background image

www.joerns.com | [email protected]

Joerns

®

 Bariatric Beds

Bari10A Model

Important Precautions 

Warning: Possible Injury Or Death.

 This product 

is intended for use as an adjustable mattress 
platform that articulates for resident/patient 
comfort with adjustable height for resident/patient 
and caregiver convenience. Use of this product 
in a manner for which it was not designed could 

result in unproven or unsafe configuration, 

potentially resulting in injury or death.

Warning: Possible Injury.

 Before adjusting bed, 

ensure that area under and near bed perimeter is 
free of people and obstructions. Failure to do so 
could result in injury.

Warning: Possible Injury.

 Keep bed in lowest 

position except when providing care (bathing, 
clothing changes, etc.). Bed should be at lowest 

convenient height for entry or exit. Failure to do so 
could result in injury.

Warning: Possible Injury Or Death.

 Floor locks 

increase bed stability and resident/patient safety. 
Floor and caster swivel locks must be locked prior 
to any resident/patient transfer or resident/patient 
use of the bed. Failure to do so could result in 
injury or death.

Warning: Possible Injury Or Death.

 Residents/

patients may become entangled in pendant cord. 
Patients with reduced mental acuity should not be 
allowed access to pendant. Unsupervised use of 
pendant could result in injury or death.

Warning: Possible Injury Or Death.

 Bed safe 

working load is 1050 pounds. This is total weight 

counting resident/patient, mattress, bedding and 

any other equipment or persons likely to be on 
bed. Do not exceed 1050-pound safe working 
load. Exceeding the safe working load could result 

in property damage, injury or death.

Warning: Possible Fire Hazard.

 Use nasal mask 

or ½ bed tent oxygen administering equipment. 
Oxygen tent should not extend below Mattress 
Support Platform. Pendant should not be placed 
in an oxygen-enriched environment such as an 
oxygen tent. Use of electrical circuits in an oxygen-

enriched environment could result in a fire hazard.

2

Warning: Possible Shock Hazard.

 Unplug 

power cord from wall outlet before performing any 

maintenance, cleaning, or service to the bed. Failure 

to do so could result in injury or death. 

Note:

 In case 

of unexpected movement, unplug bed from  

 

any outlet.

Warning: Possible Shock Hazard.

 Injury may 

result from improper routing of the power cord. 
Always follow the proper factory-installed routing 

configuration. Failure to do so could result in injury 

or death.

Warning: Possible Injury Or Death.

 Use a 

mattress that is properly sized to fit Mattress Support 
Platform, which will remain centered on Mattress 

Support Platform relative to State and Federal 
guidelines. Length and width should match Mattress 

Support Platform. Use of an improperly fitted 

mattress could result in injury or death.

Warning: Possible Injury Or Death.

 If a resident/

patient’s mental or physical condition could lead to 

resident/patient entrapment, the Mattress Support 
Platform should be left in the flat position when 

unattended. Failure to do so could result in injury or 
death.

Warning: Possible Injury Or Death.

 Use a properly 

sized mattress in order to minimize the gap between 

the side of mattress and Side Rails/Assist Devices. 
This gap must be small enough to prevent resident/
patient from getting his/her head or neck caught in 

this location. Make sure that raising or lowering bed, 
or articulating the sleep surface, does not create any 
hazardous gaps. Excessive gaps may result in injury 

or death. 

Warning: Possible Injury Or Death.

 Do not use 

any Side Rails/Assist Devices until you verify it is 
locked in place. Failure to lock assist devices may 
result in injury or death.

Warning: Possible Injury Or Death

. Do not use 

any replacement parts not manufactured, marketed, 

or provided by Joerns Healthcare on any Joerns 
bed. Use of unapproved replacement parts may 
result in injury or death.

Содержание Bari10A

Страница 1: ...Joerns Healthcare User Service Manual Joerns Model Bari10A Bariatric Bed leading bed evolution To avoid injury read user s manual before using bed...

Страница 2: ...not be placed in an oxygen enriched environment such as an oxygen tent Use of electrical circuits in an oxygen enriched environment could result in a fire hazard 2 Warning Possible Shock Hazard Unplu...

Страница 3: ...maneuverability performance push the bed from the head end To avoid injury to the resident patient and or user do not attempt to move the bed laterally with the steer mode engaged The steer wheel can...

Страница 4: ...f long term care beds and a frontrunner in addressing this critical issue Joerns Healthcare can offer you the expertise assistance and products to bring your facility into compliance Joerns Compliance...

Страница 5: ...ra 8 length for taller residents patients 18 3 4 to 33 3 4 Travel Range Integrated Scale System for resident patient weight monitoring Head and Foot End Side Rails Assist Devices Side Rails on Head an...

Страница 6: ...Lock for all functions to keep bed from accidentally operating using battery backup Note To avoid electric shock always plug bed into properly grounded hospital grade receptacle Actuator battery backu...

Страница 7: ...port Platform Release Lever Up Hold Emergency Release handle Up until Mattress Support Platform lowers to desired position Release handle if you need to stop descent 1 1 1 2 7 Figure 4 Bari Selective...

Страница 8: ...s rotate switch until it clicks into position Side Rails Assist Devices Bari10A has one Head end Side Rail and one Foot end Side Rail on both sides of bed Figure 7 Side Rails are attached and operated...

Страница 9: ...owest position with the siderails fully raised and locked when moving the bed with a resident patient in it For best maneuverability performance push the bed from the head end Warning 5th wheel must b...

Страница 10: ...p process Slide the Frame Extender out first by pulling out the latch knob on the side of the bed frame Figure 14 Begin carefully sliding the extender out and release the latch knob as soon as the ext...

Страница 11: ...t to lock all four casters individually to prevent unintended bed movement Always plug bed back into power outlet so that it is continuously charging Accessories Mattress Bari10A Bed may be equipped w...

Страница 12: ...www joerns com info joerns com Joerns Bariatric Beds Bari10A Model 12 F Figure 18...

Страница 13: ...ng Conditions Ambient Temperature 20 C to 30 C Relative Humidity 10 to 95 Non Condensing Storage and Shipping Conditions Ambient Temperature 30 C to 50 C Relative Humidity 10 to 95 Non Condensing 1 2...

Страница 14: ...will lose all stored resident patient s weight history Pressing Weight Mode button will switch back to the Weight Mode allowing you to view resident patient s total weight again Caution If you do not...

Страница 15: ...12 months or as your maintenance policy requires Electrostatic Discharge ESD Integrated circuits and semiconductors on printed circuit boards may be damaged by electrostatic discharge ESD Be sure to...

Страница 16: ...teries 1 2 3 1 2 3 4 Battery Replacement If Scale System batteries need replacement display will indicate CHANGE BATTERIES Remove Battery Cover from Foot Panel to access Scale System batteries Figure...

Страница 17: ...Use Super Lube synthetic grease or equivalent Oiling Points Keep pins and bolts oiled sample indicated by arrows in Figure 24 Oil hinge points sample indicated by arrows in Figure 25 Grease Points For...

Страница 18: ...d may be damaged Check cord for damage If cord is damaged discontinue bed usage until cord is replaced 1 2 3 4 If Adjustment Only partially occurs stops and beeps Battery may be low Plug bed into powe...

Страница 19: ...ctions may require two hands to apply equal pull force Contact Joerns Healthcare Technical Support at 800 966 6662 1 2 Mattress Support Platform sections do not articulate Pendant Control operation Se...

Страница 20: ...www joerns com info joerns com Joerns Bariatric Beds Bari10A Model 20 Appendix A Actuator Wiring Diagram...

Страница 21: ...www joerns com info joerns com Joerns Bariatric Beds Bari10A Model Appendix B Scale System Wiring Diagram 21...

Страница 22: ...www joerns com info joerns com Joerns Bariatric Beds Bari10A Model 22 Notes...

Страница 23: ...www joerns com info joerns com Joerns Bariatric Beds Bari10A Model 23 Notes...

Страница 24: ...mal use These parts such as DC batteries are not covered under the one year warranty but are covered for 90 days after date of delivery Joerns Healthcare s obligation under this warranty is limited to...

Отзывы: