background image

www.joerns.com | [email protected]

Joerns

®

 Bariatric Beds

Bari10A Model

14

Scale System    

Functions and  

Weighing Procedures 

Caution:

 5th Wheel must be disengaged to obtain 

an accurate resident/patient weight.

0.0 Zero 

With all bed linens in place and without resident/

patient in bed, press 

Zero

 button. Displayed 

message will read “PLEASE WAIT - HANDS OFF”. 

Be sure nothing touches weight-sensitive portion 
of integrated Scale System while performing 

zeroing function. In a few seconds, display will 
indicate “WEIGHT = 0.0 LB”. 

Lb/Kg 

Weight data may be viewed in either 

pounds

 or 

kilograms

. Pressing this button allows you to 

switch between display modes quickly and easily. 
Both modes will display resident/patient’s weight 

within 0.1 units of resolution (0.1 Lb. or 0.1 Kg.). 

Freeze/Resume

Freeze/Resume 

mode button provides 

customized ability to adjust resident/patient’s 

comfort by adding/ removing a pillow or blanket  

or ancillary equipment, without affecting 

 

resident/patient’s displayed weight. 

Press 

Freeze/Resume

 button. The display will 

read “FREEZE = (resident/patient’s weight).” 

 

Make all necessary adjustments to bed or  

resident/patient. When done, press 

 

Freeze/Resume

 button again to resume  

normal weighing.

Weight Change Mode

This mode is used to monitor resident/patient’s 
weight changes.

 Note: 

To enable this function 

initially, press 

Weight Change Mode

 button with 

resident/patient in bed and then press 

Zero

 button 

to zero out weight. Display will read 

 

“ WT CHG = (resident/patient weight)”. 

 

Any variation in weight will now be viewed as a  

“+” or “-” figure relative to 

zero

Weight Mode

If display shuts off before you can view weight data, 

simply press the 

On

 button to refresh display and 

view resident/patient’s weight. Display will indicate 

“WEIGHT = XXX.X LB”(or KG). 

Caution

: After initialization process is complete and 

Scale System is still in 

Weight Change Mode

do 

not

 press 

Zero

 button 

again

, or you will lose all 

stored resident/patient’s weight history. 

Pressing 

Weight Mode 

button will switch back to the 

Weight Mode

 allowing you to view resident/patient’s 

total weight again. 

Caution

: If you 

do not

 press 

Freeze/Resume 

button before adding/removing items from bed, 
the weight of those items will be reflected in the 
displayed weight, which will be hard to adjust back to 

the correct stored weight. 

Note:

 You can correct any weight discrepancy 

described above, by using 

Weight Mode

 (for 

increases) and 

Weight Change Mode 

(for 

decreases) buttons, to manually adjust displayed 

weight reading. You will need to know the weight of 
added/removed items to add/subtract from  
total weight. 

If 

Freeze/Resume

 mode is left unattended for 

more than three minutes, display will read “LEFT IN 
FREEZE - REFER TO MANUAL.” You must press 

Freeze/Resume

 button to exit this mode. 

On

Button refreshes display or initiates power for  
scale use. 

0.0

zero

Freeze

Resume

Weight

Change

Mode

On

Note:

Material - 

7 mil GLOSS POLYESTER - see finish notes below
Emboss Tool - 0.015”- 0.010” pillow emboss (for metal domes) 

6 Buttons up to edge of and including the white region (ellipses) -

Note - Two Hidden buttons - (flat non tactile) see sheet 2of 2
Selective Hardcoat to be Velvet except in region of 6 keys (matching emboss) 

and Display Window

Key embosses (six) to be Gloss 

Adhesive Mask - selective adhesive tool

No adhesive behind clear window

Adhesive 3M part no 7959MP

Display window to be Gloss 

See sheet 2 of 2 for dimensional layout, circuit layout, tail layout

and more specifications 

Edge Bleed to be added

Selective adhesive die

on its own layer - 

PMS 2715 C

Purple

PMS 425 C

Dark Gray

PMS 360 C

Green

PMS 429 C

Light Gray 

OPAQUE

WHITE

Screened  colors 

Lb/Kg

1

.8

6

"

7.42"

Weight

Mode

.06 R. TYP. 4

NOTE - SEE SHEET 2 OF 2 

FOR TWO HIDDEN KEYS

Rev

Part #:

Page 1 of 2

216-2268

Joerns Bari 10A Bed

Scale Membrane Keypad

INIT

Scott Technology, LLC
1 Jacks Hill Road
Oxford, CT 06478

Scott

Init ________/Date_________

Nexus

Init ________/Date________

Date

ECO

JP

00430

B

03/27/07

Scott

Init ________/Date_________

03/20/07

JP

-

A

Figure 21

Содержание Bari10A

Страница 1: ...Joerns Healthcare User Service Manual Joerns Model Bari10A Bariatric Bed leading bed evolution To avoid injury read user s manual before using bed...

Страница 2: ...not be placed in an oxygen enriched environment such as an oxygen tent Use of electrical circuits in an oxygen enriched environment could result in a fire hazard 2 Warning Possible Shock Hazard Unplu...

Страница 3: ...maneuverability performance push the bed from the head end To avoid injury to the resident patient and or user do not attempt to move the bed laterally with the steer mode engaged The steer wheel can...

Страница 4: ...f long term care beds and a frontrunner in addressing this critical issue Joerns Healthcare can offer you the expertise assistance and products to bring your facility into compliance Joerns Compliance...

Страница 5: ...ra 8 length for taller residents patients 18 3 4 to 33 3 4 Travel Range Integrated Scale System for resident patient weight monitoring Head and Foot End Side Rails Assist Devices Side Rails on Head an...

Страница 6: ...Lock for all functions to keep bed from accidentally operating using battery backup Note To avoid electric shock always plug bed into properly grounded hospital grade receptacle Actuator battery backu...

Страница 7: ...port Platform Release Lever Up Hold Emergency Release handle Up until Mattress Support Platform lowers to desired position Release handle if you need to stop descent 1 1 1 2 7 Figure 4 Bari Selective...

Страница 8: ...s rotate switch until it clicks into position Side Rails Assist Devices Bari10A has one Head end Side Rail and one Foot end Side Rail on both sides of bed Figure 7 Side Rails are attached and operated...

Страница 9: ...owest position with the siderails fully raised and locked when moving the bed with a resident patient in it For best maneuverability performance push the bed from the head end Warning 5th wheel must b...

Страница 10: ...p process Slide the Frame Extender out first by pulling out the latch knob on the side of the bed frame Figure 14 Begin carefully sliding the extender out and release the latch knob as soon as the ext...

Страница 11: ...t to lock all four casters individually to prevent unintended bed movement Always plug bed back into power outlet so that it is continuously charging Accessories Mattress Bari10A Bed may be equipped w...

Страница 12: ...www joerns com info joerns com Joerns Bariatric Beds Bari10A Model 12 F Figure 18...

Страница 13: ...ng Conditions Ambient Temperature 20 C to 30 C Relative Humidity 10 to 95 Non Condensing Storage and Shipping Conditions Ambient Temperature 30 C to 50 C Relative Humidity 10 to 95 Non Condensing 1 2...

Страница 14: ...will lose all stored resident patient s weight history Pressing Weight Mode button will switch back to the Weight Mode allowing you to view resident patient s total weight again Caution If you do not...

Страница 15: ...12 months or as your maintenance policy requires Electrostatic Discharge ESD Integrated circuits and semiconductors on printed circuit boards may be damaged by electrostatic discharge ESD Be sure to...

Страница 16: ...teries 1 2 3 1 2 3 4 Battery Replacement If Scale System batteries need replacement display will indicate CHANGE BATTERIES Remove Battery Cover from Foot Panel to access Scale System batteries Figure...

Страница 17: ...Use Super Lube synthetic grease or equivalent Oiling Points Keep pins and bolts oiled sample indicated by arrows in Figure 24 Oil hinge points sample indicated by arrows in Figure 25 Grease Points For...

Страница 18: ...d may be damaged Check cord for damage If cord is damaged discontinue bed usage until cord is replaced 1 2 3 4 If Adjustment Only partially occurs stops and beeps Battery may be low Plug bed into powe...

Страница 19: ...ctions may require two hands to apply equal pull force Contact Joerns Healthcare Technical Support at 800 966 6662 1 2 Mattress Support Platform sections do not articulate Pendant Control operation Se...

Страница 20: ...www joerns com info joerns com Joerns Bariatric Beds Bari10A Model 20 Appendix A Actuator Wiring Diagram...

Страница 21: ...www joerns com info joerns com Joerns Bariatric Beds Bari10A Model Appendix B Scale System Wiring Diagram 21...

Страница 22: ...www joerns com info joerns com Joerns Bariatric Beds Bari10A Model 22 Notes...

Страница 23: ...www joerns com info joerns com Joerns Bariatric Beds Bari10A Model 23 Notes...

Страница 24: ...mal use These parts such as DC batteries are not covered under the one year warranty but are covered for 90 days after date of delivery Joerns Healthcare s obligation under this warranty is limited to...

Отзывы: