82
Note
!
Malfunction manual reset function: when the machine breakdown with
malfunction, can long press "ON/OFF" button, the machine can automatically
restart immediately. W hen the machine is displayed Fault1 12, no such reset
function.
The following table shows the possibl e fault codes and status names of the
inverter.
Table 8-16 Fault codes and status names
LCD displays fault code and
status code
Name of malfunction and condition
Fault 100
Drive over current fault
State 101
PV
Array under voltage
Fault 102
Bus over-voltage
Fault 103
Retention (bus equalizing fault)
Fault 104
Radiator over heating
Fault 105
Output over-load
Fault 106
Array over-voltage
Fault 107
Array over-current
Fault 108
Inverter AC Output over-current
State109
Dry alarm
State110
Weak sunshine
Fault 111
Temperature sensor fault
Fault 112
Short circuit fault (Nonrecoverable)