information items under this menu. The following will give a detailed
introduction to each setting item.
8.3.2.1 Setting of regular stop time
This setting item is used to set the fixed stop time of the inverter, which is
convenient for users to set according to their needs and make the inverter stop
itself within the set time.
Table 8-9 Description of regular downtime setting
Timed
shutdown
information
Description
Note
Time
The inverter will stop automatically in
minutes after reaching this time
( Minutes)
。
8.3.2.2 DSP parameter setting
Used for setting key parameters of solar pump inverter system.
Table 8-10 DESCRIPTION of DSP parameter setting
DSP
Parameter
Setting Information
Description
Imotor
Motor overload current protection value, refer to the
water pump motor nameplate to set this parameter, it is
recommended to be the same as 1.2 times the motor
rated current value.