71
Pexit
When the economic mode is selected, the photovoltaic
power is higher than the exit power, and the grid exit
ensures that the inverter only uses photovoltaic energy.
(This parameter setting is recommended to be about 75%
of the load pump power, and the minimum power change
is 100W.)
S_Out
Set the inverter output load type, select "0", the inverter
is a three-phase output; W hen "1" is selected, the
inverter is single-phase output.
U-Rated
Rated output voltage, adjustable range of 130V~240V.
With the load set to UX/50Hz or UX/60Hz, UX is the rated
voltage.
ESC
Return to the previous menu.
Note
!
When the user selects solar pump inverter, the parameters in the menu of "DSP
Parameter Setting" have been set by factory, and these parameters cannot be
changed easily.
● When the output selection is changed, the inverter must be powered off. It can
only be started up again after the inverter is completely powered off. Otherwise,
the inverter and water pump may be damaged.
●When the output of the inverter switches from three -phase to single-phase, it
runs for the first time. The debugging mode must be ch anged from "Reliable" to