91
hardware
failure;
Fault205
The
grid
is
overcurrent
When
the
inverter
stops,
the
system can
start
itself
after
the
shutdown
state
disappears.
1.
Short
circuit
or
blocked turn
of the pump;
2. Hardware
failure
1.
Check
the
wiring
of
the
water pump and
whether
the
water pump can
work normally;
2. Check whether
the output of the
inverter
is
normal.
Fault206
Bus
voltage
undervoltage
When
the
inverter
stops,
the
system can
start
itself
after
the
shutdown
state
disappears.
The
grid
voltage is too
low, or the
array voltage
is too low, or
the hardware
fails.
Disconnect
the
power grid and
photovoltaic input
switch to ensure
no voltage input
to the inverter.
Check the power
grid voltage and
photovoltaic
voltage
with
a
multimeter
respectively.