72
beating recovery signal and the inverter
starting and running again. The factory default
is 30 minutes.
T-DJ
Beat dry judge time, unit is S.
OF-F
The inverter selects the overflow alarm function
of the photovoltaic pump system. When the
water level alarm function of the water storage
device is used, it needs to enable this setting
and set it as "on".
OF-Time
The upoverflow protection recovery time, the
interval time (in minutes) between the inverter
receiving the upoverflow recovery signal and
the inverter starting and running again. The
factory default is 30 minutes.
MP-Sel
=AUTO motor parameter automatic detection
input;
=Manual Motor parameters Manual input is
valid.
TestOrder
=1 Test stator resistance;
=2 Test leakage sensation;
=3 Test rotor resistance;
=4 Test static mutual inductance;
=5 Test dynamic mutual inductance;
=6
Theoretical
calculation
of
mutual
inductance.
UIPI-Sel
=AUTO motor PI parameter input automatically;
=Manual Motor PI parameter Manual input is