70
debugging.
DebugMode
This value represents the operating mode of
the inverter:
=0, indicating that the inverter is in vector mode
+ reliable type
=1, indicating that the inverter is in VF mode +
reliable type
=2, indicating that the inverter is in vector mode
+ economic mode
=3, indicating that the inverter is in VF mode +
economic mode
=4, indicating that the inverter is in RC mode
=5, indicating that the inverter is in the mode of
distributed detection of motor parameters
=6, indicating that the inverter is in the mode of
continuously detecting motor parameters
=8, indicates that the inverter is in theoretical
calculation of PI parameters
=9, indicating that the inverter is in group
control mode
=10, indicating that the inverter is in the ac
current calibration mode
VC-Sel
=0 full-order model;
=1 voltage model;
=2 Improved voltage model;
=3 Improved full-order model;
FL-Limit
The flux limit of the motor.