power change of 100W.)
SUKP
The debugging mode is effective under "group
control", adjusting slave KP.
SUISNT
The debugging mode is effective under "group
control" to adjust the slave instruction voltage.
ESC
Back To Previous Menu
Note
!
When the user selects solar pump inverter, the parameters in the menu of
"DSP Parameter Setting" have been set by factory, and these parameters
cannot be changed easily.
● When the output selection is changed, the inverter must be powered off. It
can only be started up again after the inverter is completely powered off.
Otherwise, the inverter and water pump may be damaged.
● When the inverter output is switched from three-phase to single-phase, the
commissioning mode must be changed from "0" to "4" to start up and run for
the first time. If the single-phase output is switched to three-phase output, this
step is not required.
8.3.2.3 Pump Information Setting
Used to set relevant parameters of water pump information.
Table 8-11 Description of water pump information setting (user sets according
to water pump parameters)