SECTION 3 - CHASSIS & SCISSOR ARMS
3121273
– JLG Lift –
3-9
3.6 GROUND CONTROL STATION
NOTICE
DISCONNECT MAIN POWER FROM THE BATTERIES BEFORE
ATTEMPTING TO REMOVE THE GROUND CONTROL PANEL OR
SERVICING THE ELECTRICAL SYSTEM. FAILURE TO DO SO
COULD CAUSE DAMAGE TO THE MACHINES ELECTRICAL COM-
PONENTS.
Components Location
Removal (All Models)
1. Disconnect main power at the batteries.
2. Remove the machine side cover on the left side of
the machine (ground control station/pump side).
3. Remove the (4) screws and washers attaching the
ground control panel to the frame.
4. When panel is released, rotate and position to
unplug or disconnect the desired connectors and
components on the back of the panel.
Installation
1. Check that all components are installed into the
panel and connected to the wiring harness.
2. Insert the panel into position on the machine and
align the mounting holes in the panel with the
mounting holes in the frame.
3. Attach using the (4) mounting screws and washers.
4. Reconnect the main power at the batteries, power
machine up and check machine operation.
5. Install machine side cover.
Figure 3-8. Ground Control Station Component Location
(All Models)
1.
Platform Lift/Lower Switch
2.
Key Selector Switch
3.
Ground Emergency Stop-
Button
4.
MDI - Indicator
5.
Overload Indicator (If
Equipped)
1001132360A
1
2
3
4
5
1001146979A
Figure 3-9. Ground Control Station Removal
1.
Attach Screws and
Washers
2.
Brake Release Switch
3.
Power Relay
1
1
2
3
Содержание 1932RS
Страница 1: ...Service Maintenance Manual Models 1932RS 6RS 3248RS 10RS 3121273 April 8 2013...
Страница 2: ......
Страница 12: ...viii JLG Lift 3121273 TABLE OF CONTENTS NOTES...
Страница 69: ...SECTION 3 CHASSIS SCISSOR ARMS 3121273 JLG Lift 3 37 NOTES...
Страница 73: ...SECTION 3 CHASSIS SCISSOR ARMS 3121273 JLG Lift 3 41 Figure 3 41 Arms and Platform Positioning and Support...