background image

14 

 |  JL Audio - XD1000/5v2 Owner’s Manual  

15

ENGLISH

aPPendiX C:
Xd1000/5v2 specifications:

Recommended Fuse Value:

  80A

Recommended Fuse Type:

  MAXI® or AGU

input sections:

No. of Inputs:

 Three Stereo Pairs

Input Type:

  Differential-balanced with RCA jack inputs 

Input Range:

 100mV - 8V RMS 

amplifier section:

Amplifier Topology:

  NexD™ Ultra-High Speed Class D

Power Supply:

 Unregulated MOSFET switching type

rated Power at 14.4V with less than 

 

1% tHd+noise (20Hz - 20 kHz), rms method
Main Channels, Stereo, all channels driven:  

75W x 4 @ 4 ohms, 100W x 4 @ 2 ohms

Main Channels, Bridged, all channels driven:

  

150W x 2 @ 8 ohms, 200W x 2 @ 4 ohms

Subwoofer Channel, Mono, all channels driven:

400W x 1 @ 4 ohms, 500W x 1 @ 3 ohms, 600W x 1 @ 2 ohms

rated Power @ 12.5V with less than  
1% tHd + noise (20Hz - 20 kHz), rms method
Stereo, all channels driven: 

60W x 4 @ 4 ohms, 90W x 4 @ 2 ohms

Rated Power Bridged, all channels driven: 

120W x 2 @ 8 ohms, 180W x 2 @ 4 ohms

Subwoofer Channel, Mono, all channels driven:

360W x 1 @ 4 ohms, 480W x 1 @ 3 ohms, 600W x 1 @ 2 ohms

S/N Ratio (A-weighted, 20 Hz-20 kHz noise 
bandwidth):

Main Channels: 

>104 dB referred to rated power,  

>84 dB referred to 1W 

Subwoofer Channel: 

>100dB referred to rated power, 

>80dB referred to 1W

Frequency Response:  

Main Channels: 

12 Hz - 22 kHz (+0, -1dB)               

Subwoofer Channel:

 10 Hz - 1 kHz (+0, -1dB)

Damping Factor: 

Main Channels:

 >150 @ 4 ohms per ch./ 50 Hz,  

>75 @ 2 ohms per ch. / 50 Hz

Subwoofer Channel:

 >150 @ 4 ohms per ch./ 50 Hz,  

>75 @ 2 ohms per ch. / 50 Hz

Crossover Filters:

Filter Type:

 State-variable / Sallen-Key,  with continuously 

variable cutoff frequency selection, defeatable  

Ch 1&2:

 12dB/oct. High-Pass (50-500 Hz, switchable to 500-

5000 Hz via”x10” switch)

Ch. 3&4:

 12dB/oct. High-Pass (50-500 Hz) or Bandpass (uses 

Ch 1&2 Filter Frequency as Low-Pass cutoff) 

Sub Ch:

 12dB or 24dB/oct. Low-Pass (50-500 Hz) 

dimensions (lxwxH): 

14.73”x 7.09” x 2.05” (374mm x 180mm x 52mm)

aPPendiX b:  
Precise Frequency selection Chart

“Filter Freq” 

 detent Panel actual

  number marking  Freq.
 

 Full counter-clockwise:  49

 01  . . . . . . . . . . . . . . . . . . . . . . . . . . . .49
 02  . . . . . . . . . . .

“50”

. . . . . . . . . . . .49

 03  . . . . . . . . . . . . . . . . . . . . . . . . . . . .50
 04  . . . . . . . . . . . . . . . . . . . . . . . . . . . .50
 05  . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
 06  . . . . . . . . . . . . . . . . . . . . . . . . . . . .53
 07  . . . . . . . . . . . . . . . . . . . . . . . . . . . .55
 08  . . . . . . . . . . .

“60”

. . . . . . . . . . . .57

 09  . . . . . . . . . . . . . . . . . . . . . . . . . . . .59
 10  . . . . . . . . . . . . . . . . . . . . . . . . . . . .61
 11  . . . . . . . . . . . . . . . . . . . . . . . . . . . .63
 12  . . . . . . . . . . . . . . . . . . . . . . . . . . . .65
 13  . . . . . . . . . . . . . . . . . . . . . . . . . . . .68
 14  . . . . . . . . . . . . . . . . . . . . . . . . . . . .70
 15  . . . . . . . . . . . . . . . . . . . . . . . . . . . .73
 16  . . . . . . . . . . .

“80”

. . . . . . . . . . . .76

 17  . . . . . . . . . . . . . . . . . . . . . . . . . . . .79
 18  . . . . . . . . . . . . . . . . . . . . . . . . . . . .83
 19  . . . . . . . . . . . . . . . . . . . . . . . . . . . .86
 20  . . . . . . .

“12 o’clock”

. . . . . . . .90

 21  . . . . . . . . . . . . . . . . . . . . . . . . . . . .95
 22  . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
 23  . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
 24  . . . . . . . . . .

“120”

  . . . . . . . . . . 111

 25  . . . . . . . . . . . . . . . . . . . . . . . . . . . 118
 26  . . . . . . . . . . . . . . . . . . . . . . . . . . . 126
 27  . . . . . . . . . . . . . . . . . . . . . . . . . . . 135
 28  . . . . . . . . . . . . . . . . . . . . . . . . . . . 146
 29  . . . . . . . . . . . . . . . . . . . . . . . . . . . 160
 30  . . . . . . . . . . . . . . . . . . . . . . . . . . . 174
 31  . . . . . . . . . . . . . . . . . . . . . . . . . . . 192
 32  . . . . . . . . . .

“200”

  . . . . . . . . . . 217

 33  . . . . . . . . . . . . . . . . . . . . . . . . . . . 243
 34  . . . . . . . . . . . . . . . . . . . . . . . . . . . 286
 35  . . . . . . . . . . . . . . . . . . . . . . . . . . . 339
 36  . . . . . . . . . . . . . . . . . . . . . . . . . . . 406
 37  . . . . . . . . . . . . . . . . . . . . . . . . . . . 444
 38  . . . . . . . . . .

“500”

  . . . . . . . . . . 482 

 39  . . . . . . . . . . . . . . . . . . . . . . . . . . . 483

 

  Full-clockwise:  483

aPPendiX a:
input sensitivity level setting

Following the directions below will allow the 

installer to adjust the input sensitivity of each 

amplifier channel pair simply and easily in just a 

few minutes using equipment which is commonly 

available in installation bays.

necessary equipment

• Digital AC Voltmeter

•  CD with a sine-wave test tone recorded at  

0 dB reference level in the frequency range  

to be amplified for that set of channels  

(50 Hz for subwoofer channels, 1 kHz for a 

midrange application). Do not use attenuated 

test tones (-10 dB, -20 dB, etc.).

the nine-step Procedure

 

1)  Disconnect the speaker(s) from the  

amplifier’s speaker output connectors.

2)  Turn off all processing (bass/treble, loudness, 

EQ, etc.) on the source unit, processors (if 

used) and amplifier. Set fader control to center 

position and subwoofer level control to 3/4 of 

maximum (if used to feed the XD1000/5v2).

3)  Turn all three “Input Sens.” controls all the 

way down.

4)  Set the source unit volume to 3/4 of full 

volume. This will allow for reasonable gain 

overlap with moderate clipping at full volume.

5)  Using the chart on this page, determine the target 

voltage for input sensitivity adjustment according 

to the nominal impedance of the speaker system 

connected to the amplifier outputs.

6)  Verify that you have disconnected the speakers 

before proceeding. Play a track with an 

appropriate sine wave (within the frequency 

range to be amplified by the channel you are 

adjusting) at 3/4 source unit volume.

7)  Connect the AC voltmeter to the speaker output 

connectors of the amplifier. If the channel  

pair is operating in stereo, it is only necessary  

to measure one channel. If bridged, make sure  

you test the voltage at the correct connectors  

(L+ and R–).

8)  Increase the “Input Sens.” control until the 

target voltage is observed with the voltmeter.

9)  Once you have adjusted each channel 

sectio of the XD1000/5v2 to its maximum 

low-distortion output level, reconnect the 

speaker(s). The “Input Sens.” controls can 

now be adjusted downward if the amplifier 

requires attenuation to achieve the desired 

system balance. 

Do not increase any “Input Sens.” setting for 

any amplifier channel or channel pair in the 

system beyond the maximum level established 

during this procedure. Doing so will result in 

audible distortion and possible speaker damage.

It will be necessary to readjust the  

“Input Sens.” for the affected channels if any 

equalizer boost is activated after setting the  

“Input Sens.” with this procedure. This applies  

to any EQ boost circuit, including source unit 

tone controls or EQ circuits. EQ cuts will not 

require re-adjustment. 

Due to ongoing product development, all specifications are subject to 
change without notice.

nom.

impedance

target aC Voltage

main CH

(stereo)

main CH

(bridged)

subwoofer 

CH

17.3 V

34.6 V

40.0 V

17.3 V

32.4 V

40.0 V

17.3 V

28.3 V

40.0 V

16.2 V

not recommended

38.7 V

14.1 V

not recommended

34.6 V

Содержание NexD XD1000/5v2

Страница 1: ...nsure years of musical enjoyment in your vehicle For maximum performance we highly recommend that you have your new amplifier installed by an authorized JL Audio dealer Your authorized dealer has the...

Страница 2: ...Number Installation Applications This amplifier is designed for operation in vehicles with 12 volt negative ground electrical systems Use of this product in vehicles with positive ground and or volta...

Страница 3: ...ra high speed switching technology for its four main channels and NexD high speed switching for its subwoofer channel The NexD technologies deliver outstanding fidelity and efficiency The XD1000 5v2 c...

Страница 4: ...with a direct speaker level signal applied to the amplifier and the Input Voltage switch in its High position you may use a line output converter or voltage divider to reduce the signal level Turn On...

Страница 5: ...by the HD RLC knob Input Sensitivity Controls The controls labeled Input Sens located in each channel section can be used to match the source unit s output voltage to the input stage of each channel...

Страница 6: ...or stereo source signal to both the left and right inputs of the bridged channel pair Connection of only one input will result in reduced power output increased distortion and can cause the amplifier...

Страница 7: ...ice personnel Do not attempt to service the amplifier yourself or through unauthorized repair facilities This will not only void the warranty but may result in the creation of more problems within the...

Страница 8: ...nt which is commonly available in installation bays Necessary Equipment Digital AC Voltmeter CD with a sine wave test tone recorded at 0 dB reference level in the frequency range to be amplified for t...

Страница 9: ...If you are reading sufficient voltage check your speaker connections as explained below Check to ensure that the speaker wires are making a good connection with the metal inside the terminal block Th...

Страница 10: ...h 4 Ch 6 Ch Rem Offset Signal Input Voltage Low High CH 3 L CH 4 R CH 1 L CH 1 2 CH 3 4 SUB CH CH 2 R HP Filter Mode Filter Freq Hz Input Sens Off x1 x10 Filter Mode HP Filter Freq Hz Input Sens Off B...

Страница 11: ...om the manufacturing date code Coverage may be invalidated as this date is previous to purchase date Non defective items received will be returned freight collect Customer is responsible for shipping...

Страница 12: ...stemas con toma a tierra positiva y o voltajes diferentes de 12 V pueden ocasionarse da os al producto y se anular la garant a Este producto no est certificado o aprobado para el uso en aeronaves No i...

Страница 13: ...mutaci n de velocidad ultra r pida JL Audio NexD para sus cuatro canales principales y conmutaci n de alta velocidad NexD para su canal subwoofer La tecnolog a NexD proporciona una fidelidad y una efi...

Страница 14: ...la posici n del conmutador Turn On Mode del amplificador Lea estas opciones y elija cu l se ajusta mejor a su sistema espec fico 1 Cable de encendido remoto de 12 V 2 Circuito de encendido de detecci...

Страница 15: ...roles giratorios uno en cada secci n de canal est n a modo de referencia y generalmente poseen una precisi n de 1 3 de octava o mejor Si quiere seleccionar la frecuencia l mite del filtro con un mayor...

Страница 16: ...Low High CH 3 L CH 4 R CH 1 L CH 1 2 CH 3 4 SUB CH CH 2 R HP Filter Mode Filter Freq Hz Input Sens Off x1 x10 Filter Mode HP Filter Freq Hz Input Sens Off BP HP LP Filter Mode LP Filter Freq Hz Input...

Страница 17: ...alto como de paso bajo activados Los canales 1 y 2 alimentar n los altavoces de frecuencia alta tweeters tradicionalmente en est reo con filtrado de paso alto Para operar un nico XD1000 5v2 en modo t...

Страница 18: ...ue una frecuencia indicada de 500 Hz es en verdad una frecuencia de filtro de 5000 Hz 5 kHz La curva del filtro para esta secci n est fija en 12 dB por octava Ahora seleccione una Filter Freq apropiad...

Страница 19: ...l amplificador en pocos minutos usando equipos normalmente disponibles en los talleres de instalaci n Equipos necesarios Volt metro de CA digital CD con tono de prueba de onda sinusoidal grabado a un...

Страница 20: ...a unidad fuente a mitad de volumen Si tiene el suficiente voltaje compruebe las conexiones del altavoz como se explica a continuaci n Compruebe que los cables de los altavoces tengan una buena conexi...

Страница 21: ...Sub Ch Input Mode 2 Ch 4 Ch 6 Ch Rem Offset Signal Input Voltage Low High CH 3 L CH 4 R CH 1 L CH 1 2 CH 3 4 SUB CH CH 2 R HP Filter Mode Filter Freq Hz Input Sens Off x1 x10 Filter Mode HP Filter Fre...

Страница 22: ...l c digo de fecha de fabricaci n determinar la expiraci n de la garant a en los productos que se devuelvan sin prueba de compra La cobertura puede quedar anulada dado que dicha fecha es anterior a la...

Страница 23: ...mer befindet sich auf der Unterseite des Verst rkers und auf seiner Verpackung Seriennummer Einbausituation Dieser Verst rker ist f r den Betrieb in Fahrzeugen gedacht die ber 12 Volt Systeme mit Minu...

Страница 24: ...hervorragende Klangtreue und Effizienz Der XD1000 5v2 Verst rker kann mit vielen verschiedenen Steuerger ten und System Konfigurationen betrieben werden Typischer Installationsablauf Die folgenden An...

Страница 25: ...er nahe an seinen Stromanschl ssen sichern falls mehr als ein Verst rker ber das Hauptstromkabel gespeist wird sollten Sie eine 80 A Sicherung verwenden wir empfehlen MAXI Kunststoffsicherungen Einsch...

Страница 26: ...t aggressiv hohe Frequenzen aus Ihrem Subwoofer Signal Er eignet sich vor allem f r Gel ndewagen Kombiwagen und Wagen mit Flie heck Ist der Input Voltage Schalter auf Low gestellt wird f r alle Eingan...

Страница 27: ...Offset Signal Input Voltage Low High CH 3 L CH 4 R CH 1 L CH 1 2 CH 3 4 SUB CH CH 2 R HP Filter Mode Filter Freq Hz Input Sens Off x1 x10 Filter Mode HP Filter Freq Hz Input Sens Off BP HP LP Filter...

Страница 28: ...beiliegenden Sechskant Stiftschl ssel Isolieren Sie das Ende der Kabel auf 12 mm L nge ab und f hren Sie die blanke Leitung in die Klemmleiste ein bis kein blankes Metall mehr sichtbar ist Halten Sie...

Страница 29: ...5 kHz Der Filter Abfall in diesem Bereich ist auf 12 dB Oktave festgesetzt Jetzt w hlen Sie eine angemessene Filter Freq f r Ihre Hochtonlautsprecher 5 000 Hz sind f r den Anfang in Ordnung Bevor Sie...

Страница 30: ...Frequenzbereich der jeweiligen Kan le 50 Hz f r Subwoofer Kan le 1 kHz f r Mittelhochton Anwendungen Bitte verwenden Sie keine abged mpften Testt ne 10 dB 20 dB etc Das 9 Schritte Verfahren 1 Trennen...

Страница 31: ...erkabelung und stellen Sie sicher dass die Kabel einen guten Kontakt zum Metall innerhalb der Anschlussleiste haben Die Anschl sse sind f r Kabeldurchmesser bis zu 3 25 mm ausgelegt Achten Sie darauf...

Страница 32: ...Input Mode 2 Ch 4 Ch 6 Ch Rem Offset Signal Input Voltage Low High CH 3 L CH 4 R CH 1 L CH 1 2 CH 3 4 SUB CH CH 2 R HP Filter Mode Filter Freq Hz Input Sens Off x1 x10 Filter Mode HP Filter Freq Hz I...

Страница 33: ...contacter le Service d assistance technique de JL Audio au 954 443 1100 aux heures de bureau Amplificateur 1 000 W 5 canaux avec possibilit de passer de 2 3 voies Remote Level Mode Turn On Mode All S...

Страница 34: ...yst mes lectriques sous 12 V et dont le p le n gatif est reli la masse L utilisation de ce produit dans des v hicules dont le p le positif est reli la masse et dont la tension n est pas de 12 V peut e...

Страница 35: ...mutation ultra rapide JL Audio NexD pour ses quatre principaux canaux et la technologie de commutation rapide NexD pour son canal Caisson de basse Les technologies NexD offrent une fid lit et une effi...

Страница 36: ...teur de signal 3 Circuit CC de mise sous tension d tection d offset Remote Level Mode Turn On Mode All Sub Ch Input Mode 2 Ch 4 Ch 6 Ch Rem Offset Signal Input Voltage Low High CH 3 L CH 4 R CH 1 L CH...

Страница 37: ...nt g n ralement pr cises 1 3 d octave ou mieux Si vous souhaitez s lectionner une fr quence de coupure de filtre pour un niveau de pr cision plus lev consultez le diagramme de l annexe B page 15 Si vo...

Страница 38: ...ter Freq Hz Input Sens Off x1 x10 Filter Mode HP Filter Freq Hz Input Sens Off BP HP LP Filter Mode LP Filter Freq Hz Input Sens Off 12dB 24dB Mono Subwoofer Output L R CH 1 CH 2 CH 3 CH 4 SUB SUB INP...

Страница 39: ...ous deux utilis s Les canaux 1 et 2 amplifieront les haut parleurs hautes fr quences g n ralement les haut parleurs d aigus en st r o en leur appliquant un filtre passe haut imPortant Pour utiliser un...

Страница 40: ...une fr quence indiqu e de 500 Hz quivaille en r alit une fr quence de filtre de 5 000 Hz 5 kHz La pente de filtre de cette section est fix e 12 dB octave S lectionnez maintenant une Filter Freq Fr q...

Страница 41: ...ns les bacs d installation Mat riel n cessaire Voltm tre CA num rique CD avec une tonalit de test d onde sinuso dale enregistr e un niveau de r f rence de 0 dB dans la plage de fr quence amplifier pou...

Страница 42: ...tre de l ordre des millivolts si l unit source se trouve mi volume Si vous relevez une tension suffisante v rifiez les connexions de votre haut parleur comme indiqu ci dessous Veillez ce que les c bl...

Страница 43: ...b Ch Input Mode 2 Ch 4 Ch 6 Ch Rem Offset Signal Input Voltage Low High CH 3 L CH 4 R CH 1 L CH 1 2 CH 3 4 SUB CH CH 2 R HP Filter Mode Filter Freq Hz Input Sens Off x1 x10 Filter Mode HP Filter Freq...

Страница 44: ...Fran ais 22 JL Audio XD1000 5v2 Manuel d utilisation 23 REMARQUES CONCERNANT L INSTALLATION REMARQUES CONCERNANT L INSTALLATION...

Страница 45: ...ite ne s appliquera par la suite ce produit Certains tats n autorisant pas les limites aux garanties tacites ces exclusions peuvent donc ne pas s appliquer votre situation Cette garantie vous donne de...

Отзывы: