58
Parameter Name
Description
Min MWI Subscribe
Time (mins)
The minimum time for MWI SUBSCROBE request. The
recommended value is 30 minutes.
Codec 1-5
The codec will be used for AA, VMS and conference.
2.2.15 High Available
The system supports active/standby redundant mode. It relies on MYSQL database
replication and high available software to build the system redundant as follows:
To make the redundant working smoothly, you need to the following to be prepared:
1. Two Ethernet network interface and use different VLAN or physical switch to
separate the network traffic.
2. For each service interface and IP protocol (V4 or V6), you need to have a
dedicate IP address for the server.
3. The virtual IP addresses to be used.
It supports the following high available modes:
Active/Standby Redundant for 1 Ethernet Leg