42
Parameter
Name
Description
SIP T1
The T1 timer, which is defined in milliseconds, specifies the
amount of round trip time (RTT), that the client will attempt to
send a SIP Request and expect a response. By default, the
T1 timer is set to 500ms.
SIP T2
Maximum retransmission interval for non-INVITE requests
and INVITE responses. The default value is 4000 ms.
SIP T4
Maximum duration that a message can remain in the
network. The default value is 5000 ms.
2.2.4
RADIUS
To enable RADIUS authorization and accounting message for prepaid/postpaid
billing service, it is required to setup the RADIUS service parameter here. Please
note that the RADIUS authorization request will be sent after caller DM and before
called DM. The RAIDUS start/stop billing request will also send the same calling/
called number as RADIUS authorization request to make it consisted.
Click
SYSTEM -> RADIUS
to view and change the settings.
The detail of each parameter is described as below:
Содержание UniPBX-2000
Страница 1: ...UniPBX 2000 IPV4 V6 Dual IP PBX Administrative Guide Release 1 5 1 June 2016 ...
Страница 65: ...Using the System 65 Select New Modify Delete to change the office settings The following web page will appear ...
Страница 187: ...Appendix 187 5 Appendix 5 1 Call Flow Reference 5 1 1 AA Call Flow Sample ...
Страница 188: ...188 5 1 2 VMS Flow Review Message ...
Страница 189: ...Appendix 189 5 1 3 VMS Flow Personal Greeting ...
Страница 190: ...190 5 1 4 VMS Flow Change Password ...
Страница 191: ...Appendix 191 5 1 5 Meeting Me Conference ...
Страница 192: ...192 5 1 6 Ad Hoc Conference ...
Страница 193: ...Appendix 193 5 1 7 Outgoing Calling ...
Страница 210: ...210 ...