FRL
JETYD Operations Manual
31
Figure 19. FRL Unit – Lubricator 2/3rds Full of Oil
e.
If needed, refill the reservoir as described on page 32.
f.
Reattach the lubricator by aligning the lines on the filter reservoir and FRL
body, and pushing up on the reservoir, then twisting the reservoir to lock it
in place. The black locking button should snap into its original position.
Adjusting Air Pressure
To adjust the air pressure at the regulator:
1.
If you are using a digital gauge, press the ON button on the gauge, then press the ZERO
button to set the reading to zero. Do not press the ZERO button when the system is under
pressure.