
FRL
JETYD Operations Manual
29
FRL Setup and Use
Proper setup and use of the FRL unit will ensure accurate results and safe operation. The three
components of the FRL must be checked individually to ensure correct operation.
Empty the filter reservoir before use.
Press the ZERO button on the regulator gauge before setting the operating
pressure.
Adjust the lubricator flow properly.
Fill the lubricator reservoir with pneumatic tool oil (provided with the FRL
unit).
Important FRL Operating Procedures
Only operate the unit with the air flow moving in the direction indicated by
the arrows on top of the unit.
Empty the filter reservoir before each use to remove water and sediment.
Fill the lubricator reservoir only with pneumatic tool oil before each use.
Adjust the lubricator flow to one (1) drop per ten (10) seconds (shortage of
lubrication may cause motor to sieze).
Use only the hose provided with the FRL for connection to the unit; a change
in hose length may affect tool durability and accuracy.
Emptying the Filter Reservoir
You may empty the filter reservoir of water and foreign material in two ways:
Emptying water through the release valve on the underside of the reservoir.
To use the release valve, push the valve until the water or debris drains out of
the reservoir.
Removal of the reservoir. To remove the reservoir from the FRL unit:
a.
Push down on the black square button to unlock the reservoir.
b.
Twist the filter reservoir until the two lines on the FRL body and the filter
reservoir are aligned.