JetMove D203
Jetter AG
79
8
Status Monitoring
The amplifier LEDs indicate the operating status of the digital servo amplifier.
LEDs at JetMove D203
LED
Color
Status
Description
VCC1
Green
is lit
Logic module voltage is OK
L1
Yellow
is lit
Axis is standing still (speed = 0)
L2
Yellow
is lit
A voltage of 24 V is applied to the input of
the positive limit switch (LIMIT+).
L3
Yellow
is lit
A voltage of 24 V is applied to the input of
the negative limit switch (LIMIT-).
VCC1
L 3
L 2
L 1
Notice!
The 7-segment display of the output stage indicates the operating and fault
conditions of the digital servo amplifier JetMove D203. The various display
modes are set by the Motion Setup. Mode 0 (default) is used for normal operation
and mode 1 for commissioning.
JetMove D203 - Seven-Segment Display
Mode 0: Normal Operation
Display
Status
Description
0
NOT READY TO BE
SWITCHED ON
Initialization of amplifier functions
1
SWITCH-ON INHIBIT
Initialization completed. Safe state. Is
achieved after initialising and after
acknowledging errors.
The drive controller can be switched
on.
2
READY TO BE SWITCHED
ON
Drive controller has been disabled by
software command.
The drive controller can be switched
on.
3
SWITCHED ON
DC link monitoring is activated.
4
OPERATION_ENABLED
The drive controller has been
enabled.
Содержание JetMove D203
Страница 1: ...User Manual JM D203 230 Digital Servoamplifier 60870727 We automate your success...
Страница 10: ...Table of Contents 10 Jetter AG...
Страница 36: ...4 Physical Dimensions 36 Jetter AG...
Страница 46: ...5 Technical Data 46 Jetter AG...
Страница 92: ...11 Option S1 STO 92 Jetter AG...
Страница 133: ...JetMove D203 Appendix Jetter AG 133 Appendices...
Страница 134: ...Appendices 134 Jetter AG...