JetMove D203
9.1 Error Messages
Jetter AG
81
9
Diagnostics
9.1
Error Messages
INFO
In the case of a error message, the letter "F" and two successive numbers
appear on the 7-segment display every second.
Fault Message Table for the JetMove D203
Error Number
Type of Error
Description
Response to
Errors
Troubleshooting
F 00
Hardware Errors
Internal hardware
defect
– Immediate
pulse disable
– Cut drive controller
from power lines
– Return the amplifier
for repair
F 01
Internal voltage
supply error
One or more
power supply
voltages are
beyond their limits
– Immediate
pulse disable
– Cut drive controller
from power lines
– Return the amplifier
for repair
F 03
Motor cable
breakage
The motor cable is
broken
Please be careful:
The motor cable is
tested when the
drive controller is
enabled for the
first time
– Immediate
locking of
controller
– Check the motor
cable connections
– Acknowledge failure
F 04
Overvoltage in
the DC link
A DC link voltage
of> 480 V has
been detected
– Immediate
locking of
controller
– Check input voltage
supply
– If the motor is used
as generator, reduce
the regenerating
power
– Acknowledge failure
Содержание JetMove D203
Страница 1: ...User Manual JM D203 230 Digital Servoamplifier 60870727 We automate your success...
Страница 10: ...Table of Contents 10 Jetter AG...
Страница 36: ...4 Physical Dimensions 36 Jetter AG...
Страница 46: ...5 Technical Data 46 Jetter AG...
Страница 92: ...11 Option S1 STO 92 Jetter AG...
Страница 133: ...JetMove D203 Appendix Jetter AG 133 Appendices...
Страница 134: ...Appendices 134 Jetter AG...