12 Option -JC24X
116
Jetter AG
78 : 16 = 4,... -> Turn address switch "High" to position 4
78 - (4 x 16) = 14
The decimal number 14 is converted according to the table above:
14 dec -> E hex -> The address switch "Low" has to be turned to position "E"
Fig. 35: Setting a specific IP address
To create the IP address, the address switch positions are read in once during the
boot process.
The current address switch setting can be read from register 10180.
192 . 168 . 1 . 78
Thus, octet 3 and 4 are
Switch Positions (hex):
78 : 16 = 4,... -> Switch ‘High’
78 - (4 x 16) = 14 Switch ‘Low’
78 dec
192 . 168 . 1 .
1
0
0 1
1
1
0
0
= 4
= E
High
Low
High
Low