JetMove D203
1.1 General Safety Instructions
Jetter AG
13
1.1.5
Repairs and Maintenance
Repairs to the digital servo amplifier JetMove D203 must not be carried out by the
operator. The servo amplifier JetMove D203 does not contain any parts which can
be repaired by the operator.
It must be sent to Jetter AG for repair.
The digital servo amplifier JetMove D203 is maintenance-free. Therefore, absolutely
no inspection or maintenance works are required for the operation of this device.
The controller option "-JC24X" is not maintenance-free. It is equipped with a battery
which must be replaced at regular intervals. The designed service life of the original
battery is more than 10 years. The battery condition can be checked in the following
way:
The actual battery voltage can be read out from the following special register:
The battery can provide data backup up to a voltage of 2.0 V.
If the battery needs to be replaced, please send the JetMove D203 controller to Jetter
AG.
Special register 10183
1:
Battery is okay
0:
Battery is almost flat
Special register 10184
Actual Battery voltage in 100 mV
Value range: 0 ... 255
INFO
The real-time clock and the RAM for application registers are backed up by the
same battery.
Содержание JetMove D203
Страница 1: ...User Manual JM D203 230 Digital Servoamplifier 60870727 We automate your success...
Страница 10: ...Table of Contents 10 Jetter AG...
Страница 36: ...4 Physical Dimensions 36 Jetter AG...
Страница 46: ...5 Technical Data 46 Jetter AG...
Страница 92: ...11 Option S1 STO 92 Jetter AG...
Страница 133: ...JetMove D203 Appendix Jetter AG 133 Appendices...
Страница 134: ...Appendices 134 Jetter AG...