3 Operating Conditions
34
Jetter AG
Operating Parameters
EMI - Immunity to Interference
Power Interfaces
Parameter(s)
Value(s)
Ref. standard
Burst (fast transients)
Test voltage 2 kV
Repetition frequency 5 kHz
Capacitive interference
Criterion B
(Electromagnetic environment in
industrial plants)
DIN EN 61800-3
DIN EN 61000-4-4
Operating Parameters
EMI - Immunity to Interference
Signal interfaces
Parameter(s)
Value(s)
Ref. standard
Burst (fast transients)
Test voltage 1 kV
Repetition frequency 5 kHz
Capacitive interference
Criterion B
(Electromag. envir. in ind. plants)
DIN EN 61800-3
DIN EN 61000-4-4
Guided radio
disturbances
Frequency 0.15 ... 80 MHz
Test voltage 10 V
AM 80 % at 1 kHz
Criterion A
(Electromag. envir. in ind. plants)
DIN EN 61800-3
DIN EN 61000-4-6
Operating Parameters
EMI - Immunity to Interference
Process-Related Measuring and Control Lines
Parameter(s)
Value(s)
Ref. standard
Burst (fast transients)
Test voltage 2 kV
Repetition frequency 5 kHz
Capacitive interference
Criterion B
(Electromag. envir. in ind. plants)
DIN EN 61800-3
DIN EN 61000-4-4
Impulse voltages
tr/th 1.2/50 µs, 8/20 µs
1 kV (phase to ground)
Criterion B
(Electromag. envir. in ind. plants)
DIN EN 61800-3
DIN EN 61000-4-5
Guided radio
disturbances
Frequency 0.15 ... 80 MHz
Test voltage 10 V
AM 80 % at 1 kHz
Criterion A
(Electromag. envir. in ind. plants)
DIN EN 61800-3
DIN EN 61000-4-6
Содержание JetMove D203
Страница 1: ...User Manual JM D203 230 Digital Servoamplifier 60870727 We automate your success...
Страница 10: ...Table of Contents 10 Jetter AG...
Страница 36: ...4 Physical Dimensions 36 Jetter AG...
Страница 46: ...5 Technical Data 46 Jetter AG...
Страница 92: ...11 Option S1 STO 92 Jetter AG...
Страница 133: ...JetMove D203 Appendix Jetter AG 133 Appendices...
Страница 134: ...Appendices 134 Jetter AG...