3 Operating Conditions
32
Jetter AG
The following note must be observed for the amplifier models JM-D203-JC24X-EIP...
NOTICE
The quality of the Ethernet cable has a significant influence on the EMC values
given in the following tables.
Use a CAT6 cable (S/FTP design) as Ethernet cable.
Operating Parameters
EMI - Emitted Interference
Parameter(s)
Value(s)
Reference
standard
Enclosure
• Frequency band
30 ... 230 MHz, limit 40 dB
(µV/m) in 10 m
• Frequency band
230 ... 1000 MHz, limit 47 dB
(µV/m) in 10 m
(Electromagnetic environment in
public power systems, installation
in category 2)
DIN EN 61800-3
Alternating network
current
Frequency bands:
• 0.15 ... 0.5 MHz, limit 79 dB
(µV)*
• 0.5 ... 30 MHz, limit 73 dB (µV)*
* Measuring by means of the
quasi-peak detector
(Electromagnetic environment in
public power systems, installation
in category 2)
DIN EN 61800-3
NOTICE
This is a product of restricted availability according to IEC/EN 61800-3 and may
cause radio interferences in a residential environment.
Follow the instructions below:
If this product is used in a residential environment, take appropriate
measures. One of the measures is to use additional line filters. See
"Line filter" on page 39.
Содержание JetMove D203
Страница 1: ...User Manual JM D203 230 Digital Servoamplifier 60870727 We automate your success...
Страница 10: ...Table of Contents 10 Jetter AG...
Страница 36: ...4 Physical Dimensions 36 Jetter AG...
Страница 46: ...5 Technical Data 46 Jetter AG...
Страница 92: ...11 Option S1 STO 92 Jetter AG...
Страница 133: ...JetMove D203 Appendix Jetter AG 133 Appendices...
Страница 134: ...Appendices 134 Jetter AG...