 1. Introduction 

 General Information 

Jett Plasma Medical is a low-power portable DC electrocauter. This medical device is 

used for the treatment of skin, elimination of tiny capillary bleeding, removal of small warts 
and  elimination  of  couperosis,  red  veins,  acne  and  pigment  spots.  It  also  helps  with  the 
removal of scars and stretchmarks.  

The aforementioned effects are achieved 

with a help of “a spark” discharge generated 

by  DC  voltage.  This  kind  of  discharge  generates  a  heat  that  warms  the  skin  and  desirable 
indications are treated. It is the DC fulguration (from Latin fulgur 

 lightning) that was first 

used  in  1982  at  the  ablation  of  AV  knot.  For  many  years,  AC  fulguration  has  been  used  in 
high-frequency  electrocauters  to  destroy  various  skin  protuberances  or  warts.  Generated 
sparks  in  AC  fulguration  operate  on  a  relatively  big  area  of  1  cm

2

.  Unlike  this,  Jett  Plasma 

Medical  uses  DC  fulguration  with  the  spark  flow  area  of  1mm

2

,  which  is  a  great  advantage 

because  of  its  accuracy  in  removal  of  undesirable  skin  protuberancces  or  warts  without 
damaging of the surrounding tissues.  

Using a high breakdown voltage of about 5kV, which is between the tip of the device 

and conductively connected (to the device) skin  of a patient  and maintaining the distance of 
2mm between the tip and skin (this constant distance is provided by a specific applicator), a 
spark  discharge  is  generated  with  a  corona  at  its  side.  To  be  able  to  generate  the  spark 
discharge, the air (containing free electrons) must absorb a great amount of energy leading to 
the breakdown of the air - it ceases to be an insulant and starts to conduct the electric current 

 

the discharge is generated. The air is ionized and it becomes Plasma.  

In  case  of  any  fulguration,  a  discharge  is  generated  and  that  means  that  at  any 

discharge, the gas is ionized and therefore the Plasma is created. This condition is one of the 
necessary ones, but it is not sufficient on its own.  

Only a provably trained doctor who has read and understood all the instructions given 

in  this  manual  and  who  is  acquainted  with  generally  known  dangers  and  benefits  of  the 
stimulation of the treated place with Plasma discharge can operate Jett Plasma Lift.  

Before  using  Jett  Plasma  Lift,  it  is  necessary  to  read  and  understand  all  instructions 

and  safety  precautions  in  this  Manual  and  you  are  obliged  to  follow  them.  During  the 
treatment,  make  sure  that  you  follow  all  safety  instructions.  Yu  should  also  always  be 
acquainted with indications and contraindications of the Jett Plasma Lift Medical use.  

 

 
 
 
 
 
 
 
 
 

Содержание Plasma Lift Medical

Страница 1: ...JPL Medical Date 9 9 2015 Jett Plasma Lift Medical User Manual Before you start using Jet Plasma Lift read this manual and make sure you understand all instructions and warnings and follow them close...

Страница 2: ...the Manual 10 6 Warnings and precautions 10 7 Operation of the device 13 8 Definition of plasma 17 8 1 The nature of discharge generating 18 9 Effect on cells 18 10 Use 19 11 Types of treatment 19 12...

Страница 3: ...vice and conductively connected to the device skin of a patient and maintaining the distance of 2mm between the tip and skin this constant distance is provided by a specific applicator a spark dischar...

Страница 4: ...lectrodes solid gel 51 33 mm v 300612979 Flat applicator Golden applicator with pointed tip Cone applicator AC adapter Type DA12 050EU M Input 100 240V 50 60Hz Output 5VDC max 2 0A Power max 12 VA Man...

Страница 5: ...e state The aim of the use are corrections removal of skin structures by the use of sparkle discharges generated by DC current Some of the aforementioned effects indications are not of a clinical char...

Страница 6: ...this is that the energy absorbed by body can be in cases of some applications used for targeted destruction of skin cells At the highest levels 6 7 and 8 this device is used for electro fulguration e...

Страница 7: ...used in classical surgery dermatology gynecology or dental medicine At medium intensities 5 6 when there is no considerable destruction of skin cells the device is used for the treatment of small vein...

Страница 8: ...device it must not be disposed of in communal waste Graphic sign Double insulation Graphic sign Use indoors Graphic sign Protection from a lightning Graphic sign ground galvanic connection with the de...

Страница 9: ...r storage and transport Graphic sign Range of pressure min 50 kPa max 106 kPa Graphic sign Humidity limitations min 30 max 75 Graphic sign Protect from rain Labels at the rear side of the device Flat...

Страница 10: ...explanations before you start to operate the device PRECAUTION introductory precautions All parts of the device must be connected in their places in the designed positions Use of a power adaptor other...

Страница 11: ...stick to their body during the whole time of the treatment If the patient is nt grounded the display shows the warning TAPE and the generator the Plasma is disconnected automatically TErr Two buttons...

Страница 12: ...rounding Caution Before the treatment begins the patient must be grounded by a grounding disposable electrode which is stuck on the right shoulder blade Do not touch the tip Caution Neither operator n...

Страница 13: ...the device can destroy skin cells at the intensity of 6 7 and 8 Before every application make sure twice that you have set the right intensity That means that if you do the treatment of couperosis or...

Страница 14: ...ther side to the disposable grounding electrode The message TAPE disappears from the display and the lowest intensity level 1 appears c Setting the spark discharge intensity After switching the device...

Страница 15: ...ic applicator has the same use but it does not touch skin it touches only the indifferent gel 2 Golden applicator with precise tip It is designed for face treatments and precise removals of skin pertu...

Страница 16: ...ce i Cosmetic treatment Lower intensities 1 5 Approach the tip of the device 1 to a treated place protected by an even layer of conductive indifferent gel or by a layer of a conductive serum for examp...

Страница 17: ...ectrons created by the separation of electrons from the electron shell of gases or by ionization Plasma can be also defined as the fourth form of matter In this case plasma is quasineutral and low tem...

Страница 18: ...ong the membrane and the electric voltage of the membrane is changed The Membrane potential is created and influenced by potassium and sodium cations It is difficult for sodium cations to pass through...

Страница 19: ...ted The spark channel generated by DC voltage is very slim approx 1 mm2 and therefore the treatment and the targeted destruction of cells is very precise The treatment of skin by spark discharge is a...

Страница 20: ...1st and the 2nd treatment there should be 3 free days after every other treatment a longer free period of 1 week is recommended One treatment including preparation time and aftercare takes 1 hour Afte...

Страница 21: ...ow treatment Move the tip of the device firmly slowly and carefully in the area of wrinkles 1 2 mm above the gel as you have been taught at the training If bigger areas are treated use the flat applic...

Страница 22: ...e at the tip to zero after switching off after 1 s Size 245 mm 45 mm Weight approx 350 g Range of relative air humidity 30 75 Range of environment temperature 10 to 40 o C Range of atmospheric pressur...

Страница 23: ...nd humidity Store unplugged from power supply Regular maintenance cleaning a periodical safety technical checks in given time Maintenance the operators are obliged to follow all the instructions in th...

Страница 24: ...of electrical or electronic devices may contain substance that may be harmful for the environment or health Jett Plasma Lift Medical is included in the electric waste and after the end of its lifespa...

Страница 25: ...420 602 766 759 00420 725 385 074 e mail nespor compexbrno cz export compexbrno cz The manufacturer has a system of authorized service centers For more information see www jettcosmetics cz 13 5 The De...

Страница 26: ...or A 0001 15 DATE OF MANUFACTURE 15 2 2015 Compex spol s r o Palack ho t da 105 612 00 Brno Czech Republic tel 00420 602 766 759 www jettmedical cz Golden applicator with a precise tip B 0001 15 DATE...

Страница 27: ...27 C 0001 15 DATE OF MANUFACTURE 15 2 2015...

Отзывы: