SLOW COMBUSTION FIREPLACE INSTALLATION AND OPERATION INSTRUCTIONS
Aeration settings
The burn pattern is set by controlling the air flow entering the unit. This is done by sliding the
aeration lever left and right.
Sliding LEFT reduces the airflow, and causes a slower and cooler burn.
Sliding RIGHT increases the airflow, and causes a hotter flame, that will burn out faster.
Burn cycles.
This unit is design for burning wood, efficiently. See the section of wood selection.
Firstly, pack a few small twigs and some newspaper or firelighters in the unit.
Pack the unit with hard, dry wood. Also ensure that there’s no wood resting against the window, this
would dirty the window.
Ensure that air gaps are provided between the logs. This is vital to allow the flames to burn in-
between the logs, and thereby a proper fire can be established. It is easier for the fire to spread from
the inside outward, than from the outside, inward!
Once the unit has been loaded with a full load of wood, light the wood.
Close the door to the slightly ajar latched position, and open the aeration adjuster fully. Failing to do
so might lead to smoke being spilled in to the room.
The unit is designed to function efficiently when all steel parts have reached temperature. It is
therefore important the let the unit heat up first before it should be set to a slow burn condition.
Leaving the door at the slightly ajar position, allows for a large flame, heating up the unit.