Roof Cavity
It is important that all combustible materials in the ceiling cavity be protected from the heat radiated
by the flue pipe.
It is recommended that the complete flue run in the ceiling cavity be insulated, using ceramic wool.
A gap of at least 150mm must be left between the flue pipe and any wooden beams. Should the gap
be less than 150mm, and then added insulation must be provided to prevent the wooden beams from
overheating.
It is recommended that all joints in the flue pipe, should be secured using self-drilling screws, and
sealed using heat resistant silicone. It is normally not necessary to secure a single joint that is visible
from the inside of the room. Care must be taken to ensure that the structural integrity of the flue
installation is not compromised.
(See picture on next page)