conMIG 300
8 Operation
BA-0001 • 2020-12-01
EN
-
13
8.1.4 MC 15 control system
Fig. 7
MC 15 control box
A
Knob for setting the creep speed
B
Knob for setting the wire burn-back
C
Welding type selector
D
Knob for parameter settings
E
Wire feed
F
Parameter display
Pos.
Description
A
Operating button for setting the creep speed (start speed). Press the button and use the knob
(pos. D) to set the desired value. Setting range: 10–100% of the welding speed.
B
Operating button for setting the wire burn-back time (wire length at the end of welding). Press
the button and use the knob (pos. D) to set the desired value. Setting range −10 (long wire
end) to +10 (short wire end).
C
Operating button for selecting the welding type: 2-step or 4-step. The relevant LED illuminates.
D
Knob for setting the wire speed, creep speed and wire burn-back time.
E
Operating button for activating the wire feed function. The wire is fed in for as long as the
button is pressed.
F
Display for the wire speed, creep speed and wire burn-back time. The welding current is
displayed during the welding process and when the HOLD function is active (15 sec).
A
B
D
C
E
F