EN
-
12
BA-0001 • 2020-12-01
8 Operation
conMIG 300
8.1.3 MC 5 control system
,
Fig. 6
MC 5 control box
A
Display for current (A) or
voltage (V)
B
LED indicator of the parameter
shown on the display (A)
C
Parameter selection switch
D
Gas test / increase parameter
E
Wire feed / decrease parameter
F
Knob for the wire speed
G
LED indicator for the active
welding type
H
Welding type selector
I
Wire feed speed display
Pos.
Description
A
Display for the welding current in amperes or the welding voltage in volts as well as the creep
speed and wire burn-back time.
B
LED indicator of the parameter that is currently shown on the display (A) (creep speed, wire
burn-back time or welding current).
C
Operating button for selecting the creep speed, wire burn-back time, material thickness and
welding current (spot time if spot welding is activated).
D
Operating button for activating the gas test. In setup mode, operating button for increasing
the creep speed and wire burn-back time (LED pos. B) flashes.
E
Operating button for activating the wire feed function. In setup mode, operating button for
lowering the creep speed and wire burn-back time (LED pos. C) flashes.
F
Knob for setting the wire speed in m/min.
G
LED indicator for the active welding type: 2-step, 4-step, 2-step spot.
H
Operating button for selecting the welding type: 2-step, 4-step, 2-step spot.
I
Display of the wire speed in m/min. Flashing dot: HOLD function active.
A
B
C
D
E
F
G
H
I