conMIG 300
6 Putting into operation
BA-0001 • 2020-12-01
EN
-
7
Welding voltage selection
12-step voltage selector switch
Control functions
Wire feeder and spot welding time can be adjusted
Cooling the power source with a quiet fan
The fan is activated by a thermostat and does not begin to operate until the power source has warmed up.
It switches off during pauses in welding as soon as the power source has cooled down again.
Thermal overload protection
If the permitted operating temperature is exceeded due to an extremely high load or ambient temperature,
an integrated thermal switch disconnects the welding current.
Central connection socket
The central connection socket allows the welding torch to be connected and disconnected quickly.
All electronic components are installed in the metal housing. The power supply is provided via a separate
connecting cable. For the connection voltage and power consumption:
See 3.1 Technical data on page EN
6 Putting into operation
DANGER
Risk of injury due to unexpected start
The following instructions must be adhered to during all maintenance, servicing, assembly, disassembly
and repair work:
• Switch off the power source.
• Close off the gas supply.
• Close off the compressed air supply.
• Disconnect all electrical connections.
• Switch off the entire welding system.
CAUTION
Risk of injury
Increased noise pollution.
• Wear personal protective equipment: ear protectors.
WARNING
Electric shock
Dangerous voltage due to defective cables.
• Check all live cables and connections for proper installation and damage.
• Replace any damaged, deformed or worn parts.
WARNING
Risk of injury
Feet may be crushed due to sudden rolling movement of the power source.
• Inspect the safety of the machine.
• Position on flat, even surfaces only.
CAUTION
Risk of injury
Heavy weight.
• Ensure that you slow down in good time when moving the device.