Shutdown, Recommissioning and Disposal
6. Shutdown, Recommissioning and Disposal
No special measures are necessary for brief shutdowns of the
unit (e.g. a few days).
For longer periods of inactivity over several weeks or for example
over winter we recommend:
Removing the suction lines from the chemical supply tanks
and flushing them with water.
Closing the chemical supply tanks, storing them in a cool,
dry location and protecting them from UV radiation.
Flushing the peristaltic pumps with water. Operating the
controller in manual mode.
Disconnecting the unit from the mains.
Stopping the sample water supply.
Draining the water sampling station and peristaltic pumps.
To do this open all the valves and unscrew the temperature
sensor or the plug.
Keep the glass electrodes (pH and REDOX electrodes)
damp. Fill the transport caps with water and fit them on the
electrodes or place the electrodes in a container with water.
Store the electrodes in a frost-free environment.
NOTICE!
Over long periods of inactivity an oxide layer forms on
the copper electrode of the chlorine measuring cell.
This must be removed when the unit is recommis-
sioned. (see chapter 7, maintenance)
Recommissioning
After a long period of inactivity, e.g. winter break, the TOPAX
DX SMART must be operated for approx. 1 … 4 h before the
measuring inputs are calibrated with the housing closed. This
will prevent the high impedance measuring inputs of the pH and
REDOX electrodes from failing due to humidity (condensation).
For short periods of inactivity we recommend leaving the TOPAX
DX SMART switched on.
Disposal of old units
If the equipment is to be disposed of after its service life, it must
be thoroughly rinsed and dewatered. The equipment was manu-
factured in accordance with the ROHS guideline and the waste
electrical equipment legislation. The manufacturer will take care
of disposal if the equipment is returned free of charge. It is not
part of domestic waste. When returning the unit please also fill
out and return the declaration of no objection.
•
•
•
•
•
•
•
•
Содержание EASYPOOL SMART 02
Страница 39: ...EASYPOOL SMART 02 Operating Manual 39 Notes Notes...
Страница 40: ...40 EASYPOOL SMART 02 Operating Manual Notes...
Страница 44: ......