EASYPOOL SMART 0 Operating Manual | 11
Controller
Terminal
Function
33
A
Internal
PC interface
Interface for software-update
34
B
35
36
Alarm relay as com-
mon alarm
Normally Closed (N.C.)
37
Middle contact
38
Normally Open (N.O.)
39
PE
Protection conductor
90 … 64 V AC
40
41
N
Neutral conductor
4
43
44
L
Phase
45
46
5-fold Input block (part no. 78403):
Terminal
Function
Cable colour
51A
+
Free chlorine
Chlorine measuring cell CS10
Electrode mating copper/platinum or
silver/platinum
CS10 (Cu/Pt)
Cu : blue (-)
Pt : red (+)
CS10 (Ag/Pt)
Ag : purple(-)
Pt : red (+)
5A
-
51B
+
not used
5B
-
53
+
pH value
54
-
55
+
REDOX
56
-
57
Temperature
(Polarity at wish)
58
59
not used
60
61
Input module (3x) (part no. 78404) optional:
Terminal Function
71
not used
7
73
74
+
0 mA passively (without supply to the sensor)
Conductivity measurement
75
-
76
not used
77
78
outputs board (order no. 78399)
Termi-
nal
Output
81 +
Digital output
(optocoupler)
DO7
programmable ***)
8 -
83 +
DO6
84 -
85 +
DO5
86 -
87
Relay output
DO4
88
89
DO3
90
91
DO
9
93
DO1
94
95
DO0
96
***) The routing of the configurable outputs is displayed according to the
configuration and can be selected at any time in the Service >> HW-Status
menu
IMPORTANT!
To prevent the output relays from bonding in the case
of a short in the load circuit, it must be separatly
protected with the maximum relay switching cur-
rent. For inductive loads, apply a protective circuit to
the contacts of the relays (spark suppression). The
manufacturer recommends the use of the interfer-
ence suppression module / spark suppression device
(part no. 78614).