30
MAINTENANCE
- The hydraulic circuit of the load transfer is protected against overload with a
pressure relief valve set at
120 bars
.
- Regularly grease the hinges of the cylinders and the trunnions of the sleeves which
slide over the bases.
7).
Hydraulic stand.
SAFETY
Never put your foot under the stand.
FUNCTION
It replaces on high tonnage machines, the angle transmission mechanical stand.
The user can with less effort adjust the height of the equipment when hitching it to
the tractor.
USE
To send the oil in the stand-cylinder, operate the lever from top to bottom.
For return, slowly open the valve of the pump.
MAINTENANCE
Change oil at least once a year.
Hand pump: capacity
4 litres
Mineral oil
Hydro 32 Unil
Or equivalent
12.
Cleaning.
Cleaning method
1.
To avoid accidents, never clean the equipment when it is in operation. The
equipment should be in rest position, unhitched from the tractor with the PTO and
hydraulics disconnected.
2.
When cleaning the equipment, if you need to turn the moving floor on in order to
empty it, put the equipment back in work position and carry out this operation from
the tractor’s driving station after having checked that no one is in the projection
area of the beaters and moving floor.
3.
After carrying out this operation, continue cleaning the equipment.