Chapter 10
Test Results
Copper results
OneExpert DSL User’s Guide
88
22052280, Revision 001
April 2014
Resistance
You measure resistance to test line continuity and quality, and to detect corrosion, shorts, opens,
and faults.
The OneExpert DSL is able to measure resistance in the presence of noise and foreign voltage, but
the accuracy may be reduced, depending on the noise level.
Resistance should be measured with the line disconnected, so that the battery voltage and CO/
Exchange termination don't affect the measurement.
Normal resistance should be at least 5 M
; lower values indicate the presence of faults.
describes the resistance result.
Distance to short
This result measure the distance to the short. A resistance measurement of 4 k
or less typically
indicates a short. For values greater than 4 k
, this function is disabled.
describes the distance to short result.
Leakage
Leakage is a resistance measurement using higher voltage.
describes the leakage result.
Table 22
Resistance result specifications (no ambient)
Range (
)
Resolution (
)
Accuracy
0 to 999
1
2% ± 2.5
1.0K to 9.99K
10
2%
10.0K to 99.9K
100
2%
100.0K to 999K
1K
2%
1.0M to 9.9M
10K
6.5%
10.0M to 100M
100K
10%
Table 23
Distance to short result specifications
Range (feet)
Resolution
Range (meters)
Resolution
0 to 3000
30 feet
0 to 999
9 meters
3000 to 30,000
100 feet
1000 to 10,000
30.5 meters
Table 24
Leakage result specifications (no ambient)
Range (
)
Resolution (
)
Accuracy
0 to 49.99
1
2% ± 2.5
Содержание OneExpert DSL
Страница 1: ...OneExpert DSL User s Guide...
Страница 2: ......
Страница 16: ...About this Guide Conventions OneExpert DSL User s Guide xiv 22052280 Rev 000 April 2014...
Страница 50: ...Chapter 3 Utilities Using the tray menu OneExpert DSL User s Guide 34 22052280 Revision 001 April 2014...
Страница 60: ...Chapter 4 DSL Testing After running the test OneExpert DSL User s Guide 44 22052280 Revision 001 April 2014...
Страница 68: ...Chapter 6 HPNA Testing Testing the HPNA network OneExpert DSL User s Guide 52 22052280 Revision 001 April 2014...
Страница 78: ...Chapter 7 Testing with SmartIDs Whole Home Check OneExpert DSL User s Guide 62 22052280 Revision 001 April 2014...
Страница 112: ...Appendix A Troubleshooting Resolving problems OneExpert DSL User s Guide 96 22052280 Revision 001 April 2014...
Страница 119: ......