Page 25
6.4. Other functions
6.4.1 Standby
1) Press and hold the "Current Setting Encoder" key for 2s to start the countdown. After the
3s countdown is over, the panel displays "F01"; press the key again to enter standby
response time settings.
2) Rotate the "Current Setting Encoder" to adjust the standby response time, increasing
clockwise and decreasing counterclockwise. (The standby response time includes four levels:
0, 5, 10, 15, where 0 means disabled, and other numbers correspond to the response time, in
minutes. The default value is 10.)
3) After adjusting the standby response time, press the "Current Setting Encoder" key to
save the current settings.
4) Press the welding mode key
to complete the operation and exit.
5) The standby function is only available in TIG mode. If the machine is not used within the
set response time, it will enter standby state, and only the middle bar of the first digit on the
display panel will flash at a frequency of 1Hz. The machine will wake up immediately when
the torch trigger, operation panel, or remote controller is used.
Standby function indicator
6.4.2 Input overvoltage and undervoltage protection