Page 11
4. Technical parameters
Item
Unit
Parameters
Model
/
TIG200PACDC PFC
TIG200PACDC
Input voltage
VAC
AC115±15%~230V±15%
AC230V±15%
Input frequency
Hz
50/60
50/60
Rated input current
(AC230V)
A
21.1@TIG 22.7@MMA
25@TIG 27@MMA
Rated input current
(AC115V)
A
32.2@TIG 34.1@MMA
/
Rated input power
(AC230V)
kVA
4.7@TIG 5.6@MMA
6.0@TIG 7.0@MMA
Rated input power
(AC115V)
kVA
3.5@TIG 3.9@MMA
/
Output current range
(TIG)
A
230V: 5~200
115V: 5~160
5~200
Output current range
(MMA)
A
230V: 10~160
115V: 10~120
10~160
Rated working voltage
(AC230V)
V
18@TIG 26.4@MMA
18@TIG 26.4@MMA
Rated working voltage
(AC115V)
V
16.4@TIG 14.8@MMA
/
Arc force current range
A
0~40
0~40
Hot start current range
A
0~80
0~80
No-load voltage
V
65
60
VRD voltage
V
11.5
11.5
AC output frequency
Hz
20~250
20~250
AC balance
%
20~60
20~60
Base current
A
5~200
5~200
Pulse frequency (DC)
Hz
0.5~200
0.5~200
Pulse frequency (AC)
Hz
AC frequency: 20Hz
Pulse frequency: 0.5-2Hz
AC frequency: 20Hz
Pulse frequency: 0.5-2Hz
AC frequency: 250Hz
Pulse frequency: 0.5-25Hz
AC frequency: 250Hz
Pulse frequency: 0.5-25Hz
Pulse duty factor
%
10~90
10~90
Pre-flow time
S
0~3
0~3
Post-flow time
S
0~15
0~15