 Regulatory Statement 

 

CE Notice 

The 

 symbol  indicates  compliance  of  this  JASCO  system  to  the  EMC  (Electromagnetic 

Compatibility) and Low Voltage Directives of the European Community. This symbol indicates that 
this JASCO system meets the relevant basic safety and health requirements of the EC Directive 
based on the following technical standards: 
 

  EN55011  --  "Industrial,  scientific  and  medical  (ISM)  radio-frequency  equipment  –  Radio 

disturbance characteristics – Limits and methods of measurement" -- Group 1, Class A. 

 

WARNING!

:  This is a Class A product.  In a domestic environment this product may 

cause radio interference, in which case the user may be required to take 
corrective measures. 

 

  EN61000-6-1 -- "Electromagnetic compatibility (EMC) Part 6-1:Generic standards – Immunity 

for residential, commercial and light-industrial environments" 

  IEC61000-3-2  --  "Electromagnetic  compatibility  (EMC)  Part  3-2:Limits  –  Limits  for  harmonic 

current emissions (equipment input current up to and including 16A per phase) " 

  IEC61010-1  --  "Safety  requirements  for  electrical  equipment  for  measurement,  control  and 

laboratory use – Part 1:General requirements" 

  A "Declaration of Conformity" in accordance with the above standards has been made and is on 

file at JASCO EUROPE srl, Via Confalonieri 25, 22060 CREMELLA (LC), Italy. 

 
FCC Statement (for USA only) 

 
Federal Communications Commission Radio Frequency Interference Statement 
 

WARNING!

:

 

This  equipment  generates,  uses,  and  can  radiate  radio  frequency 
energy. If it is not installed and used in accordance with the instruction 
manual, it may cause interference to radio communications. It has been 
tested and found to comply with the limits for a Class A computing device 
pursuant  to  Part  15  of  FCC  Rules,  which  are  designed  to  provide 
reasonable  protection  against  such  interference  when  operated  in  a 
commercial  environment.  Operation  of  this  equipment  in  a  residential 
area  is  likely  to  cause  interference,  in  which  case  the  user  at  his  own 
expense will be required to take whatever measures may be required to 
correct the interference. 

Содержание V-530

Страница 1: ...P N 0302 0256B November 2000 Model V 530 550 560 570 UV VIS Spectrophotometer Hard ware Function Manual...

Страница 2: ...symbol refer to the instrument manuals to protect the instrument against damage WARNING A WARNING indicates a potentially hazardous situation which if not avoided could result in serious injury or eve...

Страница 3: ...GROUND Figure 1 Warning Labels on the V 530 Rear Panel WARNING FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE ONLY WITH FUSE OF THE SPECIFIED TYPE AND CURRENT RATINGS Only use fuses of the desi...

Страница 4: ...Rear Panel 2 Warning for carrying These instruments weigh as follows V 530 16 0 kg V 550 30 5 kg V 560 32 0 kg V 570 33 0 kg When carrying the instrument hold the carrying handle at the bottom of the...

Страница 5: ...missions equipment input current up to and including 16A per phase IEC61010 1 Safety requirements for electrical equipment for measurement control and laboratory use Part 1 General requirements A Decl...

Страница 6: ...Before using the instrument please read this instruction manual carefully and make sure that the contents are fully understood This manual should be easily accessible to the operator at all times duri...

Страница 7: ...cy The instrument may not function properly when near a strong magnetic field or high frequency source 8 Avoid vibration from vacuum pumps electric motors processing equipment and machine tools 9 Avoi...

Страница 8: ...party Disclosure of confidential information regarding software Modification of software Use of software on multiple workstations network terminals or by other methods not applicable under a network l...

Страница 9: ...BLE PARTS NOT SUPPLIED BY AN AUTHORIZED JASCO DISTRIBUTOR 5 CORROSION DUE TO THE USE OF IMPROPER SOLVENTS SAMPLES OR DUE TO SURROUNDING GASES 6 ACCIDENTS BEYOND JASCO S CONTROL INCLUDING NATURAL DISAS...

Страница 10: ...Electrical System 7 2 2 V 550 560 570 Spectrophotometers Optical System 9 2 2 1 Optical System 9 2 2 2 Electrical System 11 3 Nomenclature and Functions of Components 12 3 1 V 530 Spectrophotometer O...

Страница 11: ...ne Flatness 24 4 4 2 Wavelength Repeatability 25 4 4 3 Wavelength Accuracy 26 4 5 Replacement of Consumables 27 4 5 1 Replacement of Fuse 27 4 5 2 Lamp Replacement and Adjusting the Light Source Mirro...

Страница 12: ...hotometric mode Abs T R Photometric range 2 000 to 3 000 Abs 0 to 200 T Photometric display 10000 T 2 to 5 Abs Four digits and symbol Photometric repeatability 0 001 Abs 0 to 0 5 Abs 0 002 Abs 0 5 to...

Страница 13: ...Deuterium lamp 190 to 350 nm Halogen lamp 330 to 900 nm Light source changeover wavelength Any wavelength between 330 and 350 nm can be selected Wavelength range 190 to 900 nm Wavelength repeatabilit...

Страница 14: ...ght 460 W 595 D 260 H mm excluding protrusions 30 5 kg Note Photometric repeatability photometric accuracy and baseline flatness are the values obtained more than one hour after the Power switch is tu...

Страница 15: ...power when temperature variation is within 5 C wavelength 250 nm response Slow and spectral bandwidth 2nm Baseline flatness 0 001 Abs value obtained after baseline correction when temperature variati...

Страница 16: ...region 0 3 to 3 Abs NIR region Photometric display 0 0 to 200 0 T 2 to 5 Abs Four digits and symbol Displays up to 000 0 T and 0 000 Abs Photometric repeatability 0 001 Abs 0 to 0 5 Abs 0 002 Abs 0 5...

Страница 17: ...elength 850 to 2500 nm spectral bandwidth 8 nm Detector Photomultiplier tube Pbs photoconductive cell Power requirements 100 115 200 220 230 240 V 10 180 W Dimensions and weight Main unit 460 W 595 D...

Страница 18: ...the reference sample such as a solvent The light that has passed through the sample and the reference sample is alternately incident upon the silicon photodiode D D Ref Sam F G WI M5 M2 M BS 3 S2 S1 D...

Страница 19: ...rial 2 Accessory input Sccessory output Coarse Adj Fine Adj Detector Amp Battery Main unit 320 240 10 6 CPU ROM RAM I O I O LCD ROM Card RAM Card Autozero Goto WL File Start Stop Print iRM Touch key L...

Страница 20: ...and Halogen WI lamp 340 to 2500 nm for use in the VIS NIR region The light from the light source is converged and enters the monochromator It is dispersed by the grating in the monochromator and the l...

Страница 21: ...Light source M Mirror S Slit F Filter G Grating M8 beam splitter PM Detector Sam Sample beam Ref Reference beam W window WI D2 Light source M Mirror S Slit F Filter G Grating M8 beam splitter PM UV V...

Страница 22: ...and enters the microcomputer The signal processed by the microcomputer is displayed on the output device as digital data or a spectrum Light source changeover wavelength drive slit drive filter drive...

Страница 23: ...lid to open and gain access to the reference and sample cell holders The cell holder closest to the front of the instrument is the sample cell holder Fixing screws Fixes the sample chamber in positio...

Страница 24: ...emote module power cable Printer Connector for connecting the printer plotter cable Serial A Connector for connecting the communication cable to DS or iRM Serial B Connector for connecting theRS 232C...

Страница 25: ...reference and sample cell holders The cell holder closest to the front of the instrument is the sample cell holder Fixing screws Fix the sample chamber in position To mount the optional sample chambe...

Страница 26: ...ime lag fuses iRM PS Accepts the remote module power cable Serial A Connector for connecting the communication cable to DS or iRM Serial B Connector for connecting the RS 232C cable Recorder Terminal...

Страница 27: ...tion Fixing screws Fix the sample chamber in position To mount the optional sample chamber loosen these screws and remove the standard sample chamber Sample cell holder Mount the cell containing the s...

Страница 28: ...for operating the monochromator printer etc Stop Press to stop measurement Print Press to print out data measurement parameters etc File Press to save load parameters and data GotoWL Press to move to...

Страница 29: ...ete remove the sample from the sample chamber 4 2 Cleaning the Sample Chamber If a sample is spilt in the sample chamber quickly wipe up the spillage with gauze or similar material remove the sample c...

Страница 30: ...nual Baseline flatness Refer to Section 4 3 1 Wavelength repeatability Refer to Section 4 3 2 Wavelength accuracy Refer to Section 4 3 3 4 3 1 Baseline Abs 0 line Flatness This check should be perform...

Страница 31: ...thin the following criterion V 530 criterion Within 0 001 Abs 1000 200 nm V 550 560 570 criterion Within 0 001 Abs 850 200 nm Figure 4 1 Baseline flatness V 550 560 570 4 3 2 Wavelength Repeatability...

Страница 32: ...ing Speed 10 nm min End 654 nm Start 658 nm Data Pitch 0 1 nm End 654 nm Display 0 100 Data Pitch 0 025 nm No of Cycles 3 Display 0 100 Cycle Time 1 sec PMT Voltage 300 V No of Cycles 3 Cycle Time 1 s...

Страница 33: ...1 in Section 4 3 2 2 Start Spectrum Measurement from the Spectra Manager window and set the following parameters Parameters for spectrum with an emission line at 656 1 nm V 530 measurement parameters...

Страница 34: ...emission line at 656 1 nm Figure 4 6 D2 lamp spectrum with emission line at 486 0 nm 4 Wavelength accuracy is normal if the measurement result in within the following criteria V 530 criteria Within 65...

Страница 35: ...rument on 1 Select Spectrum from the main menu and measure the baseline of the entire region after setting the following parameters Refer to Section 5 4 of the Operations manual Response Medium Scanni...

Страница 36: ...following parameters V 530 measurement parameters V 550 560 570 measurement parameters Phtmtrc mode Sam Phtmtrc mode Sam Response Fast Response Fast Start WL 658 nm Band width 0 5 nm End WL 654 nm St...

Страница 37: ...nterval 0 1 nm End WL 654 nm Scan speed 40 nm min Data interval 0 025 nm No of Cycles 1 Scan speed 10 nm min Lower scale 0 No of Cycles 1 Upper scale 100 Lower scale 0 Upper scale 100 HT Voltage 300 V...

Страница 38: ...om the outlet before replacing a fuse Use the following procedure when replacing a fuse 1 Turn off the power and unplug the AC power cable from the outlet 2 Insert a flat headed screwdriver into the f...

Страница 39: ...he screws required for lamp replacement 2 When handling the lamp ware clean cloth gloves Never handle the lamp with bare hands 3 Never touch the mirror or any other optical elements by hand 4 If the l...

Страница 40: ...ce unit V 550 560 570 Replacement of Deuterium lamp 1 Slide the outer lid of the light source unit to remove it and then remove the inner lid Fig 4 8 2 Pull out the Deuterium lamp from the socket Fig...

Страница 41: ...nstrument 2 Start Time Course Measurement from the Spectra Manager window and set the following parameters V 530 measurement parameters V 550 560 570 measurement parameters Photometric mode Sample Pho...

Страница 42: ...ed if the beam from the lamp is not correctly incident upon the entrance slit troubles will arise such as lack of luminous energy bend of the baseline and deviation of the measurement value Whenever t...

Страница 43: ...uterium lamp 1 Turn on the instrument 2 Select Envir from the main menu to display the Environment menu 3 Select Single Beam from the Environment menu to display the single beam measurement screen Ref...

Страница 44: ...ete description of the problem When checking the instrument observe the following warnings and cautions WARNINGS 1 Do not directly look at the light ultraviolet light emitted from the Deuterium lamp a...

Страница 45: ...cal JASCO distributor WI lamp does not light Lamp burnt out Check the WI lamp to see if it has burnt out Replace the lamp with a new one if burnt out Refer to Section 4 5 2 D2 lamp does light Lamp bur...

Страница 46: ...r than 320 nm is not stabilized D2 lamp is Off Set the D2 lamp to On Refer to the Operations manual The performance at wavelengths longer than 400 nm is not stabilized WI lamp is Off Set the WI lamp O...

Страница 47: ...36...