5-7
TAIKO Service Manual
CHAPTER
5
© 2006 Japan Cash Machine Co.Ltd. All rights reserved.
# of
Flashes
Sensor Position
1
ROM Error
2
JAM inside Acceptor
3
Bill remains inside transport path
4
Adjustment Error
5
Motor Error
6
Entrance Solenoid Error
7
Exit Solenoid Error
8
Sensor operation at the abnormal timing
1
Penetration (Upper to Lower) Right IR
2
Penetration (Upper to Lower) Left IR
3
Penetration (Upper to Lower) Right RED
4
Penetration (Upper to Lower) Left RED
5
Penetration (Upper to Lower) Right NIR
6
Penetration (Upper to Lower) Left NIR
7
Penetration (Upper to Lower) Right BLUE
8
Penetration (Upper to Lower) Left BLUE
1
Penetration (Lower to Upper) Right IR
2
Penetration (Lower to Upper) Left IR
3
Penetration (Lower to Upper) Right RED
4
Penetration (Lower to Upper) Left RED
5
Penetration (Lower to Upper) Right NIR
6
Penetration (Lower to Upper) Left NIR
7
Penetration (Lower to Upper) Right BLUE
8
Penetration (Lower to Upper) Left BLUE
5-3-4. Transport Motor Reverse Rotation Test Procedure
Test the condition of the Transport Motor reverse rotation.
1. Set the switch No.1 and 2 ON and supply the power to the TAIKO unit.
2. Set the switch No.1 OFF to start the test. Ther transport motor rotates reverse.
3. If the Blue LED lamp blinks despite the number, the test is completed. No error is
found.
- If TAIKO’s red LED lamp lights, the Transport Motor has a
problem.
5-3-5. Aging Procedure
1. Set the switch No.1, 2 and 4 ON and supply the power to the TAIKO unit.
2. Set the switch No. 1 OFF to start the test. TAIKO unit repeates the following operation.
LED lamp lights => Motor rotates foward => Motor rotates reverse
3. If an sensor error is found while aging, the TAIKO stop the operation. You can speci-
fied the error of the sensor with the number of the LED lamp blinks.