TAIKO Servic e Manual
5-2
CHAPTER
5
© 2006 Japan Cash Machine Co.Ltd. All rights reserved.
5-1. Error Codes
Number of Red flashes of the LED lamp indicates the Error of TAIKO unit.
LED lamp is located in the middle of the faceplate.
See=> 1-3. Component Names
5-1-1.
Error Codes
# of Flashes
Diagnostic Description
2
ROM error
3
Banknote remains inside ejection slot
4
Banknote remains inside transport path
5
EEPROM read/write error
6
Motor error
8
Entrance solenoid error
9
Exit solenoid error
12
Fraud detected
5-2. Trouble Shooting
When an error message appears or trouble is occures and the TAIKO unit does not work
properly, recover the TAIKO unit following the instruction below.
5-2-1. General Troubles
Symptom/Error Message
Possible Causes
Recovery Action
Power is not supplied to the
acceptor.
Verify the specified voltage and ground
are supplied to appropriate pins of the
interface connector.
Connection is wrong.
Verify if all harnesses and connectors
are connected properly.
Verify if the connector pin has been any
bend, missing, broken.
Verify if the specified voltage is supplied
to the appropriate pin. See=> Chapter
2 Specifications
Software is not downloaded.
Download the appropriate software to
the TAIKO unit. See=> 4-1.Download
CPU/Sensor Board is
Corrupted.
Perform Acceptance Test. See => 4-2.
Adjustment
If the test result is NG, replace the
CPU/Sensor Board. See=> Chapter 6
Replacement procedure
After CPU/Sensor board is replaced,
perform the adjustment. See=> 4-2.
Adjustment
Acceptor is not working
(Acceptor does not accept
any bill)