emPC-CXR
(
Hardware Manual
)
•
Installation
3 - 11
Rev. V1.2
©
Janz Tec AG
3.2
Connectors and Operators
Below the VGA connector you find an M5 thread for an additional earth connection. EMI Tests were
passed without extra earth connection. However, during EMI testing, earth connection was established
with the shields of the IO cables (VGA, LAN, …).
The green power LED between the USB connectors lights when the system is running. It does not
light when the system is in power down mode even if power is applied at the power connector.
NOTICE
Do not actuate connectors when power is applied.
NOTICE
All connectors (M12/M8/DSUB) are not sealed when no mating connector is present. Use
a screw plug to seal unused connectors.
NOTICE
Mechanical actuation of M12/M8 connectors is prohibited below -25 °C.
LAN1
LAN2
POWER
CAN/Serial 2
Digital IO
CAN/Serial 1
USB1
USB2
figure 3: front view with connectors