www.janitza.de
UMG 96-PA
77
16.
Technical Data
General
Net weight (with connectors attached)
approx. 250 g
Packaged weight (incl. accessories)
approx. 500g
Battery
Lithium type CR2032, 3V (approved as per UL 1642)
Life cycle of the backlighting
40000h
(Backlighting diminishes over this
time period to approx. 50%)
Transport and storage
The following details apply for devices that are transported and stored in the original packaging.
Free fall
1m
Temperature
K55 (-25°C to +70°C)
Relative humidity
0 to 90% RH
Environmental conditions for operation
The device is suitable for weather-protected, non-mobile use.
Protection class II as per IEC 60536 (VDE 0106, Part 1).
Measurement temperature range
K55 (-10°C .. +55°C)
Relative humidity
0 to 75 % RH
Operating height
0 .. 2000m over NN
Pollution degree
2
Installation position
vertical
Ventilation
External ventilation is not required.
Protection from foreign objects and water
- Front
- Back
- Front with seal
IP40 as per EN60529
IP20 as per EN60529
IP54 as per EN60529
Supply voltage
Option 230V
Nominal range
AC 90 V - 277 V (50/60 Hz) or DC 90 V - 250 V;
300 V CATIII
Power consumption
max. 4.5 VA / 2 W
Option 24V
Nominal range
AC 24 V - 90 V (50/60Hz) or DC 24 V - 90 V;
150 V CATIII
Power consumption
max. 4.5 VA / 2 W
Operating range
+-10% of nominal range
Internal fuse
not exchangeable
Type T1A / 250 V DC / 277 V AC as per IEC 60127
Recommended overvoltage protective device for the
Line protection (UL approval)
Option 230 V: 6 - 16 A (Char. B)
Option 24 V: 1 - 6 A (Char. B)
Recommendation for the maximum number of devices on the line circuit breaker:
Option 230V : Line circuit breaker B6A: max. 4 devices / Line circuit breaker B16A: max. 11 devices
Option 24V : Line circuit breaker B6A: max. 3 devices / Line circuit breaker B16A: max. 9 devices
Содержание UMG 96-PA
Страница 7: ...www janitza de UMG 96 PA 7 ...
Страница 67: ...www janitza de UMG 96 PA 67 ...
Страница 81: ...www janitza de UMG 96 PA 81 ...