Page 12
ENGLISH
Jandy
®
Pro Series TruClear
™
Chlorine Generating System
|
Installation & Operation Manual
NOTE
If the fl ow direction of the water does not match the
arrows on the housing, the cell will malfunction.
4.
Let the system dry per instructions provided by the
glue manufacturer. When the glue is dry, start the
system and check for proper water fl ow.
WARNING
To avoid property damage, serious injury or death, do not
operate the electrolytic cell without water circulation or if
cell housing is damaged or improperly assembled.
Retrofi tted Installation
The retrofi tted installation is a factory designed TruClear
with threaded unions built into the housing unit. This
method can be used to replace an existing chlorine
generator or as a new installation.
1.
Determine the desired location for the cell as the
last piece of equipment before the return inlet to
the pool, on a pipe segment at least 16 inches long.
The cell must be mounted upright on pipe which
runs within ± 5º of level (parallel to the ground).
The cell cannot be mounted on a vertical, or sloping
pipe.
NOTE
The cell must be installed on a 16 Inch (40cm)
horizontal length of pipe after the heaters, pumps, and
fi lters, as the last piece of equipment in the circulation
plumbing system just before the pool (see Figure 1).
3.4
Installing the Cell
WARNING
The Jandy Pro Series chlorine generating device
must be installed outdoors only. The cell must be
installed horizontally with the cord facing upwards to
avoid buildup of flammable gases which can result in
FIRE OR EXPLOSION.
Standard Installation
The standard installation consists of plumbing the
housing unit of the TruClear directly into the pool
plumbing system, without the use of threaded unions.
1.
Determine the desired location for the cell as the
last piece of equipment before the return inlet to
the pool, on a pipe segment at least 16 inches long.
The cell must be mounted upright on pipe which
runs within ± 5º of level (parallel to the ground).
The cell cannot be mounted on a vertical, or sloping
pipe.
NOTE
The cell must be installed on a 16 Inch (40cm)
horizontal length of pipe after the heaters, pumps, and
fi lters, as the last piece of equipment in the circulation
plumbing system before the pool inlet (see Figure 1).
2.
Make the appropriate cuts in the pipe where you
will be installing the cell. The gap between the cuts
should be 6 inches.
3.
Remove the cell from the housing and plumb the
housing into the pipe, making sure that the fl ow
indicator arrows on the housing match the fl ow
direction of the water. Pipes must be clean and dry
before gluing.