Page 24
ENGLISH
Jandy
®
Pro Series TruClear
™
Chlorine Generating System
|
Installation & Operation Manual
Problem
Possible Cause
Corrective Action
Power pack and cell turned on too long.
If chlorine output is set at the lowest setting
and it consistently provides excessive
chlorine levels, decrease operation time as
much as necessary.
No display on LCD
(screen is blank).
No power to unit.
Check the connection to the pump timer
(see Section 3.5).
Check if GFCI tripped.
Display says “No
Flow”. Caused by
insufficient water flow
through the cell.
Caused by insufficient water flow through
the cell.
NOTE
When the Flow light is on,
the chlorine output will be
turned off.
Check and clean the pump and skimmer
baskets.
Dirty filter.
Clean the filter.
Poor connection between cell and power
pack
Check for secure connection to power pack
Closed valves.
Check and correct all valve alignments.
Pump fails to provide sufficient water
flow.
Check for correct operation of the pump.
Make sure pump is sized properly for
required flow rate.
The display says “Lo
Tmp/Lo Salt”.
Salt level is well below 2,500 ppm,
depending on water temperature.
Maintain a salinity level of 3,000 ppm -
3,500 ppm (see Section 4.6 or contact your
local pool professional).
Calcium buildup in the cell
Clean the Cell
NOTE
Salinity readings are taken after 5 minutes and at regular 5 minute intervals. The Salt
warning will turn on when the salt level drops well below 2,500 ppm and it will remain on
until the salt level is raised to 3,000 ppm or slightly above.
Cell life expired.
Replace the cell.
A combination of low water temperature
(35°-65°F / 2°-18°C) and lower salt
levels (1,500 - 2,000 ppm).
Check salt level in pool water. If level is
between 3,000 - 3,500 ppm, no action is
necessary. If salt levels are lower than
2,500 ppm, raise the salinity level to 3,000
- 3,500 ppm (see Section 4.6).
NOTE
Salt levels above 4,500 ppm
may cause corrosion damage.
Salt level too low.
Not enough salt added to pool.
Add salt to pool until salinity returns to
3,000 ppm
(see Section 4.6).
Leak in pool.
Repair pool.