Technical Data and Specifications
18
Revision 2.0c – 30 August 2013
HPC User Manual
9.0
Technical Data and Specifications
PARAMETER
SPECIFICATION
Active-Neutral Supply Voltage
100-230VAC ±10% Full size neutral required
Supply Frequency
40-66Hz
Supply Protection
10K Amps
Rated Insulation Voltage
430VAC Phase to Phase, 250VAC Phase to Neutral
Rated Output Current
10 Amps per channel
Minimum Power/Channel
25W
Maximum Dissipation
<24 W/channel
Electric Shock protection
SELV
System Earth Type
MEN
Output Protection
Thermal/magnetic circuit breakers
Maximum Ambient Temperature
40ºC
Maximum Altitude
2000m
Over-temperature cutout
Soft limit starts at 92°C, Full cutout at 100°C
Control Signal
ANSI E1.11:2004 DMX-512-A
ANSI E1.20:2006 RDM
DMX Input
5 pin AXR male / female
Snapshot Scenes
2
Test Function Level
Individual Channels @ 100%
All Channels @ 10% steps
LED Indicators
SIGNAL, ERROR, TERM, IC
Phases A, B, and C
Ingress protection
IP20
Internal Separation
Form 1
Environment
B
Size
478mm (w) x 133mm (h) x 355mm (d)
Weight
19.5kg with 220us risetime
Rack mounting requirements
Three x 19” rack spaces / standard spacing for mounting holes.
Inlet air ventilation on right side, exhaust air on left side (when
looking from front of unit). Rack must include suitable ventilation.
Power inlet at rear right.
Содержание HPC AIRGAP