Installation
Unit location
In order to achieve maximum cooling capacity, the installation location for the condensing unit should be carefully selected.
Install the condensing unit in such a way so that hot air ejected by the condensing unit cannot be drawn in again (short circuit of hot
discharge air). Allow sufficient space for maintenance around the unit.
Ensure that there is no obstruction to air flow into or out of the unit. Remove obstacles which block air intake or discharge.
The location must be well ventilated, so the unit can draw in and distribute plenty of air thus lowering the condensing temperature.
To optimize the unit running conditions, the condenser coil must be cleaned at regular intervals.
The indoor units can be mounted directly to a wall or to the ceiling utilizing the fixing holes on the rear of the unit or on the top of the
unit. No additional brackets are required. Position the indoor unit where the optimum airflow can be achieved. Avoid locating in corners
or in alcoves which may restrict airflows. A minimum 10mm rawlbolt type fixing is required with a large steel washer to bear the unit
weight.
It is important to ensure that the wall/ceiling is able to withstand the unit weight and that all fixings are secure.
Both indoor and outdoor units must be level in all directions.
X
X
Содержание JCC2
Страница 1: ...JCC2 CELLAR AND PRODUCT COOLERS ISSUE 01 02 2016 CELLAR COOLER RANGE TECHNICAL MANUAL ...
Страница 17: ...Issue 01 02 2016 Page 17 Drawings Indoor unit dimensions 25E 40E ...
Страница 18: ...Issue 01 02 2016 Page 18 Drawings Indoor unit dimensions 50E 60E ...
Страница 24: ...Issue 01 02 2016 Page 24 Certification ...
Страница 25: ...Issue 01 02 2016 Page 25 THIS PAGE IS LEFT BLANK INTENTIONALLY ...