Issue: 01.02.2016
Page 21
Technical Information
Electronic Controller (Dixell XR02CX)
To check the setpoint temperature:
Press and release the SET button.
To change the setpoint temperature:
Press the SET button for more than 3 seconds
The setpoint value is displayed and the °C or °F led starts flashing.
To change the setpoint value press the
▲
or
▼
button within 10 seconds.
To retain the new setpoint press the SET button button again or wait 10 seconds.
To start a manual defrost:
Press the defrost button (top left ) for more than 2 seconds.
To lock the buttons:
Press the
▲
and
▼
buttons together for more than 3 seconds. The ‘OF’ message will be displayed and the buttons are now
locked to prevent unauthorized access.
To unlock the buttons:
Press the
▲
and
▼
buttons together for more than 3 seconds. When the ‘ON’ message is displayed the buttons will be
unlocked.
To change a parameter value (selected parameters):
Enter the programming mode by pressing the SET and the
▼
buttons together for more than 3 seconds (°C or °F LED starts
blinking). The first parameter (Hy) is displayed.
Press the SET button to display the parameter value.
Use the
▲
and
▼
buttons to change the parameter value.
Press the SET button to store the new value and move to the next parameter.
To exit the programming mode press the SET and
▲
buttons together or wait 15 seconds without pressing a button.
To enter the hidden parameter menu (full parameter list):
Enter the programming mode by pressing the SET and
▼
buttons together for 3 seconds (°C or °F LED starts blinking).
Release the buttons, and then press the SET and
▼
buttons for more than 7 seconds. L2 will be displayed followed by the
first parameter (Hy).
You are now in the hidden menu.
Select the required parameter.
Press the SET button to display the parameter value.
Use the
▲
and
▼
buttons to change the parameter value.
Press the SET button to store the new value and move to the next parameter.
To exit the programming mode press the SET and
▲
buttons together or wait 15 seconds without pressing a button.
Содержание JCC2
Страница 1: ...JCC2 CELLAR AND PRODUCT COOLERS ISSUE 01 02 2016 CELLAR COOLER RANGE TECHNICAL MANUAL ...
Страница 17: ...Issue 01 02 2016 Page 17 Drawings Indoor unit dimensions 25E 40E ...
Страница 18: ...Issue 01 02 2016 Page 18 Drawings Indoor unit dimensions 50E 60E ...
Страница 24: ...Issue 01 02 2016 Page 24 Certification ...
Страница 25: ...Issue 01 02 2016 Page 25 THIS PAGE IS LEFT BLANK INTENTIONALLY ...