Manual
JAKKA Control Kit 4
29
www.jakkagroup.com
Connector
Pin
Pin Description
J9
(Stelvio, BS95/7A + CT84)
(Stocko, MKF 2800 series)
1
2-5
3-6
4-7
Earth
Output heating element relay #1 (230VAC)
Output heating element relay #1 (230VAC)
Output heating element relay #1 (230VAC)
Heating outputs
Usable output current is TBD.
Maximal cable length is TBD meter.
Connector
Pin
Pin Description
J10
Programming Header
Connector to re-program the MN processor using an Senso
Argus-to-ICP device. (See also J15)
Connector
Pin
Pin Description
J13
(Stelvio, BS95/6A + CT84)
(Stocko, MKF 2800 series)
1
2
3
4
5
6
Earth
Exhaust fan Neutral
Exhaust fan 230V
Fan overheat stat 1 (230VAC)
Fan overheat stat 2 (230VAC)
Fan Overheat Neutral
Overheat (230VAC)
Exhaust fan
Overheat
Fan
Fan overheat stat connected to pin 5 and 6
makes that it is placed in series with the
heating element relays (ECO device).
Triac output, max output is 480W
Maximal cable length is 1 meter
Connector
Pin
Pin Description
J15
Programming Header
Connector to program processor WD using an Senso Argus-
to-ICP device. (See also J10)
Connector
Pin
Pin Description
J16
(Molex, Minifit Jr. 2x4 receptacle
with terminals 5556)
1 - 5
2 - 6
3 - 7
4 - 8
5V Power Supply (optional for sensor)
0..10V input
Fan proof switch input (NC)
Modbus
Sensor input
The maximum cable length is 1 meter.
The sensors connected to the control should be free from the
appliance earth.
Connector
Pin
Pin Description
J21
(Molex, Minifit Jr. 2x3 receptacle
with terminals 5556)
1
2
3
4
5
6
Fan 1 PWM out
Fan 1 Hall puls
Vss
Fan 2 PWM out
Fan 1 Hall puls
12 volt
PWM Fan
The maximum cable length is 1 meter.