Xonic 5L
7/23
5. Lead Switch operation function.
Bring neodymium magnet into contact with SW101, SW102 to operate the special function of
ultrasonic water meter.
(1)
Instant display function
- Bring neodymium magnet into contact with Lead Switch SW101.
- Unit is changed from m³ to m³/h.
(2)Delta-T display function
- Bring neodymium magnet into contact with Lead Switch SW102.
- No unit.
(3)Sound Speed display function.
- Bring neodymium magnet into contact with Lead Switch SW101 + SW102 simultaneously.
- No unit.
(4) Actual zero operation function.
- Turn the power OFF.
- After LCD display screen is off, bring neodymium magnet into contact with Lead Switch SW102.
- Turn the power ON.
- The icon and firmware version will be displayed on LCD for about 30 seconds to 1 minute.
- Completed when total flow and m³ unit are displayed on LCD.
- Once actual zero is completed, it starts to operate in Factory mode.(If no battery sign, then it is
Factory mode )
(5) Switch to Factory mode
- Turn the power OFF.
- After LCD display screen is off, bring neodymium magnet into contact with Lead Switch SW101.
- Completed when total flow and m³ unit are displayed on LCD.
- It starts to operate in Factory mode.( If no battery sign, then it is Factory mode)
(6) Switch to User mode
- Turn the power OFF.
- Once LCD screen is off, turn the power ON.