RM/TM-1405GE Series
54
Configuring the Camera
Category / Feature
Read/
Write
Value Range
Default Value
Visibility
Level
GevPersistentDefaultGatewa
y
RW 000.000.000.000
- 255.255.255 000.000.000.000 Expert
GevCurrentIPConfigurationPe
rsistenIP
RW On
Off
Off
Beginner
ImageSizeControl
SensorDigitizationTaps RW
One
One
Expert
WidthMax RO
0
– 1392
Beginner
HeightMax RO
0
- 1040
Beginner
Width
RW
0 to (WidthMax - OffsetX)
Beginner
Height
RW
0 to (HeightMax - OffsetY)
Beginner
OffsetX RW
WidthMax
- Width
Beginner
OffsetY RW
HeightMax
- Height
Beginner
PixelFormat RW
Monochrome:
Mono8
Mono10
Mono10Packed
Bayer:
BayerRG8
BayerGB8
BayerRG10
BayerGB10
Monochrome:
Mono8
Bayer:
BayerRG8
Beginner
ScanMode RW
A_1392x1040
UserProgrammable
A_1392x1040
Beginner
UserScanAreaStart
RW
0 to (1040 - UserScanAreaLines
- 1)
0
Beginner
UserScanAreaLines
RW
0 to (1040 - UserScanAreaStart) 500
Beginner
TestImageSelector RW
Off
DeviceSpecific
IPEngineTestPattern
Off
Beginner
LUT
LUTMode RW
Linear
Gamma45
Knne
Linear
Beginner
KneeX1 RW
0
- 255
255
Beginner
KneeY1 RW
0
- 255
255
Beginner
KneeX2 RW
0
- 255
255
Beginner
KneeY2 RW
0
- 255
255
Beginner
LUTInversion RW
Execute
Command
Beginner