RM/TM-1405GE Series
44
Configuring the Camera
This table show possible signals each input line can accept (“(D)” specifies factory defaults):
Signal Name / Input Pin
I0
I1
I2
I3
I4
I5
I6 I7
External_Trigger_In_Pin6 X(D)
X
X
X
X
X
X X
External_VD_In_Pin7 X
X(D)
X
X
X
X
X X
External_HD_In_Pin9 X
X(D)
X
External_INT_In
X
X(D)
X
X
Internal_FDV_Out X
X
X
X
X X
Internal_LDV_Out X
X
X
X
X
Internal_CAM_STROBE_Out X
X
X
X
X(D)
X X
PLC_ctrl0 X
X
X
X
X
X
PLC_ctrl2 X
X
X
X
PLC_ctrl3
X
X
X
PLC_Q2 X
X
X
X
PLC_Q3
X
X
X
X
PLC_Q6 X
X
X
X
PLC_Q7
X X
X
X
Counter1Gt
X
X
X
Counter1Eq
X
X
X
Timer1Out X
X
X
X(D)
Timer2Out X
X
X
X(D)
Timer3Out
X
X
X(D) X
Timer4Out
X
X
X
5.8.2
ControlBits
There are 3 Control Bits: PLC_ctrl0, PLC_ctrl2, and PLC_ctrl3. Note that PLC_ctrl1 is not available.
The control bits can be used as software triggers by toggling between two states: True and False.
True sets the signal High, while False sets the signal to Low.
When a bit is toggled on the host software, a Write Register command is sent to the camera. The
arrival time of the packet depends on current network traffic therefore is varied. These are
recommended for testing purposes. For more precise trigger usage please use an external input
trigger signal thru the 12-Pin connector. For a constant periodic trigger signal please use the Pulse
Generators (Timers).