AcquisitionFrameCount RW
1-255
1
Beginner
AcquisitionStart
RO Execute
Command
Beginner
AcquisitionStop RO
Execute
Command
Beginner
AcquisitionRecordingWrapAr
ound
RW False
True
False
Expert
BlockBufferCount
RO
Depends on image size.
Expert
BlockBufferCurrentIndex WO
0 to (BlockBufferCount – 1)
Expert
ExposureMode RW
Off
ContinuousProgrammable
AsyncNoShutter
PulseWidthControl
AsyncProgrammable
Off
Beginner
AsyncProgrammable RW
0 - 2079
Factory Set
Beginner
ContinousProgrammable RW
0
- 1052
Factory Set
Beginner
TriggerPolarity RW
ActiveLow
ActiveHigh
ActiveLow Beginner
AnalogControls
GainRaw RW
71
- 231
Factory Set
Beginner
VTop RW
0
– 255 (Max 220
recommended)
Factory Set
Guru
VBottom RW
0
– 255
Factory Set
Guru
AutoBlackLevel RW
Enable
Disable
Factory Set
Guru
AutoBlackLevelRaw RW
0
– 255
Factory Set
Guru
CountersAndTimersControls
TimerSelector RW
Timer1
Timer2
Timer3
Timer4
Timer1
Beginner
TimerDelayRaw RW
1-65535
1024
Beginner
TimerDurationRaw RW
1-65535
4096
Beginner
TimerGranularityFactor RW
1-65535
0
Beginner
TimerTriggerActivation RW
RisingEdge
LevelHigh
FallingEdge
AnyEdge
LevelLow
RisingEdge Beginner
TimerTriggerSource RW
PLC_Q
Continuous
PLC_Q
Beginner