RM/TM-1405GE Series
24
Operation
Table 3
Video Output (Vertical Timing)
Vertical
Timing
Full Scan Area
User Scan Area (SP:x, TL:y)
Number of lines
30fps (
μ
s)
Number of lines
30fps (
μ
s)
J
1053 33864.48
(nfp+11)+nrp+y
((nfp+11)+nrp+y)*32.12
K
13 418.08
(nfp+11)+nrp
((nfp+11)+nrp)*32.16
L
1040 33446.40
y
y*32.16
M
0 0
0
0
N
0 0
0
0
P
3 96.48
nrp+6
(nrp+6)*32.12
Q
3 96.48
3
96.48
R
7 225.12
nfp+5
(nfp+5)*32.16
Where
3.9
External HD Locking and External VD Reset
Table 4
External HD Locking and External VD Reset (Horizontal Timing)
Horizontal Timing
Number of pixels
30fps (
μ
s)
eA <1
<0.02
eB 160
3.20
eC 1448
28.96
eD 15
0.30
Table 5
External HD Locking and External VD Reset (Vertical Timing)
Vertical Timing
Full Scan Area
User Scan Area (SP:x, TL:y)
Number of lines
30fps (
μ
s)
Number of lines
30fps (
μ
s)
eE <1 <32.16
<1
<32.16
eF 9 289.44
9
289.44
eG 1404 45152.64
(nfp+2)+nrp+y
((nfp+2)+nrp+y)*32.16
eH 0
0
0
0
Содержание RM-1405GE
Страница 2: ......
Страница 15: ...Installation 15 RM TM 1405GE Series Figure 4 Back Focus Set Screw Locations ...
Страница 22: ...RM TM 1405GE Series 22 Operation 3 7 Camera Timing Charts ...