Configuring the Camera
51
RM/TM-1405GE Series
iii.
Set PLC_Q5_Variable0 to One. (Integration signal always on.)
Example 2
: Setting the camera to accept internal trigger signal generated via Timer 1:
Set ExposureMode to one of Asynchronous modes.
Setup the Timer (Pulse Generator)
a. Set TimerSelector to Timer1.
b. Set TimerTriggerSource to Continuous.
c. Set TimerDurationRaw, TimerDelayRaw, TimerGranularityFactor according to
values below.
i.
These are example values only; other combinations can also be used.
ii.
TimerFrequency tells you the rate of the trigger, hence frame rate.
<0.5
fps
1 fps
5 fps
TimerDurationRaw 200
200
200
TimerDelayRaw 10000
4550
750
TimerGranularityFactor 7000
7000
7000
Setup SignalRoutingBlock
a. Goto IPEngine > ProgrammableLogicController > SignalRoutingBlock
b. Set PLC_I4 to “Internal CAM_STROBE_Out”.
c. Set PLC_I7 to Timer1Out.
Setup the ProgrammableLogicController (PLC) to route the Timer1 output to the camera’s trigger
line.
a. Goto IPEngine > ProgrammableLogicController > LookupTable
i.
Set Q4 > PLC_Q4_Variable0 to PLC_I7 (Trigger Line)
ii.
Set Q0 > PLC_Q0_Variable0 to PLC_I4 (Strobe output)
iii.
Set Q5 > PLC_Q5_Variable0 to One. (Integration signal always on.)
Example 3:
Setting up Integration Signal routing from external source:
Goto IPEngine > ProgrammableLogicController > SignalRoutingBlock
Set PLC_I3 to External_INT_In
Goto IPEngine > ProgrammableLogicController > LookupTable
Set Q5 > PLC_Q5_Variable0 to PLC_I3. (Integration signal always on.)
5.9
Register Map
Category / Feature
Read/
Write
Value Range
Default Value
Visibility
Level
AcquisitionAndTriggerControls
AcquisitionMode RW
Continuous
SingleFrame
MultiFrame
ContinuousRecording
ContinuousReadout
SingleFrameRecording
SingleFrameReadout
Continuous Beginner